Ansicht
Dokumentation

CPI7F9D - Line &23 attached to network interface &30, underrun errors threshold reached. ( OS/400 )

CPI7F9D - Line &23 attached to network interface &30, underrun errors threshold reached. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   Vendor Master (General Section)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI7F9D
Line &23 attached to network interface &30, underrun errors threshold reached.

Message Long Text :

Cause . . . . . : The number of underrun errors has exceeded the threshold value given by the system. One of the following may have caused the problem:
-- The communication subsystem may be overloaded.
-- Trying to do too many service functions, such as communications trace, on the communication subsystem (even if the services may not be used).
Recovery . . . : You may choose to ignore this message because your line is operational. If you are not satisfied with the operation of your communications equipment, reduce your communications work load by varying off lines or by ending service functions that are not needed. To determine which lines and/or network interfaces are active and use the same communications controller card, use the work with hardware resources (WRKHDWRSC) command and specify type (*CMN). You may change the frequency of occurrence of this message by adjusting the value of the UNDERRUN and THRESHOLD parameters, using the CHGLINIDLC command. If the problem still persists, run the ANZPRB command to report the problem.
Technical description . . . . . . . . : A sufficient number of underrun errors were detected over time such that the error counter exceeded the threshold limit.

- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


BAL Application Log Documentation   TXBHW - Original Tax Base Amount in Local Currency  
This documentation is copyright by IBM.

Length: 3274 Date: 20240328 Time: 153643     sap01-206 ( 3 ms )