Ansicht
Dokumentation

CPI8E0D - Line &23 threshold information. ( OS/400 )

CPI8E0D - Line &23 threshold information. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8E0D
Line &23 threshold information.

Message Long Text :

Cause . . . . . : The communications subsystem is overloaded by one of the following:
-- The line speeds are too high.
-- There are too many lines attached to the same communications processor card.
-- Too many service functions are being performed on the communications subsystem.
Recovery . . . : You may choose to ignore this message because your line is operational. If you are not satisfied with the operation of your communications equipment, reduce the line speeds or the number of lines. To determine what other lines are active, you may choose to vary off the line and vary it on using the vary configuration (VRYCFG) command with RESET (*YES) specified. The VRYCFG command will display a message for each active line. Then you may choose to vary off these lines to reduce the work load, and vary on the line in error to reset this line. You may also end service functions that are not needed. The threshold function may be turned off or changed in the threshold (THRESHOLD) parameter on the CRTLINSDLC command. To report the problem, start problem analysis (ANZPRB command).
Technical description . . . . . . . . : The counter for hardware overrun errors reached the value specified by the THRESHOLD value in the CRTLINSDLC command.

- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG