CPI8E26 - Line &23 threshold information. ( OS/400 )

CPI8E26 - Line &23 threshold information. ( OS/400 )

BAL_S_LOG - Application Log: Log header data   BAL Application Log Documentation  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8E26
Line &23 threshold information.

Message Long Text :

Cause . . . . . : The following may have caused the problem:
-- The X.21 network did not respond.
Recovery . . . : You may choose to ignore this message because your line is operational. If you are not satisfied with the operation of your network, consult the local telephone company to have the line tested to verify line quality. The threshold function may be turned off or changed in the threshold (THRESHOLD) parameter in the CRTLINSDLC command. To report the problem, start problem analysis (ANZPRB command).
Technical description . . . . . . . . : The X.21 network failed to complete the connection to the remote location within the time specified in the T3A time-out parameter. This occurred many times and caused the counter for T3A time-out errors to reach the value specified by the THRESHOLD value in the CRTLINSDLC command.

- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


BAL_S_LOG - Application Log: Log header data   CPI1466 during Backup  