Ansicht
Dokumentation
CPI8E37 - Line &23 threshold information. ( OS/400 )
ROGBILLS - Synchronize billing plans BAL Application Log DocumentationThis documentation is copyright by IBM.
Message : CPI8E37
Line &23 threshold information.
Message Long Text :
Cause . . . . . : The following may have caused the problem:
-- An incorrect number may have been specified for the CNNNBR value when the controller description was created.
Recovery . . . : You may choose to ignore this message because your line is operational. Verify that the correct number is specified for the CNNNBR value. The threshold function may be turned off or changed in the threshold (THRESHOLD) parameter on the CRTLINSDLC command. To report the problem, start problem analysis (ANZPRB command).
Technical description . . . . . . . . : The threshold limit for the X.21 network 22 call progress signal reached the limit specified by the THRESHOLD value in the CRTLINSDLC command. The X.21 network detected a format or sequence error with the calling procedure.
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28
Message File : QCPFMSG
Library Message File : QSYS2924
BAL_S_LOG - Application Log: Log header data Fill RESBD Structure from EBP Component Structure
This documentation is copyright by IBM.