Ansicht
Dokumentation

CPI8E78 - Line &23 threshold information. ( OS/400 )

CPI8E78 - Line &23 threshold information. ( OS/400 )

Addresses (Business Address Services)   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8E78
Line &23 threshold information.

Message Long Text :

Cause . . . . . : One of the following may have caused the problem:
-- The environment may be electrically noisy.
-- The auto call unit may not be properly grounded.
Recovery . . . : You may choose to ignore this message if you have been successful in establishing a switched connection. Refer to the IBM Systems Hardware Information Center Planning information for information about electrical requirements and noise problem considerations. Consult the modem manufacturer to determine the proper grounding technique to use. The threshold function may be turned off or changed in the threshold (THRESHOLD) parameter on the CRTLINBSC command. To report the problem, start problem analysis (ANZPRB command).
Technical description . . . . . . . . : This error indicates that the present-next-digit (PND) circuit has been found in error many times and caused a threshold error.

- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


General Data in Customer Master   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.