Line &23 failed, token-ring line is no longer connected to the ring.

Message Long Text :

Cause . . . . . : The token-ring adapter has received a Remove Ring Station MAC frame. This frame is sent by the token-ring LAN manager on the token-ring network instructing a ring station to remove itself from the ring. As a result, the token-ring adapter has de-inserted from the token-ring network.
Recovery . . . : Verify the correct operation of the token-ring LAN manager in the token-ring network. If the problem persists, press F14 to run problem analysis.
Technical description . . . . . . . . : This message provides status about the ring.

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28