Ansicht
Dokumentation

CPI8E9B - Error on network interface &30. ( OS/400 )

CPI8E9B - Error on network interface &30. ( OS/400 )

PERFORM Short Reference   Vendor Master (General Section)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8E9B
Error on network interface &30.

Message Long Text :

Cause . . . . . : The following may have caused the error:
-- The local data circuit-terminating equipment may not be working correctly.
-- The local data communications cable may not be working correctly.
-- The local communications adapter card may not be working correctly.
Recovery . . . : Press F14 to run problem analysis.
Technical description . . . . . . . . : The local data circuit-terminating-equipment failed to drop the Clear-To-Send (CTS) signal in the required time after the Request-To- Send signal dropped.

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27

Message File : QCPFMSG
Library Message File : QSYS2924


ROGBILLS - Synchronize billing plans   General Material Data  
This documentation is copyright by IBM.

Length: 3231 Date: 20240418 Time: 091624     sap01-206 ( 3 ms )