CPI8EBB - Line &23 threshold information. ( OS/400 )
ABAP Short Reference General Material DataThis documentation is copyright by IBM.
Message : CPI8EBB
Line &23 threshold information.
Message Long Text :
Cause . . . . . : One of the following may have caused the problem:
-- Too many dialing digits were specified in the controller description.
-- No number was specified for the CNNNBR value when the controller description was created.
Recovery . . . : You may choose to ignore this message if you have been successful in establishing a switched connection. Verify the dialing digits specified. Correct the number that was specified for the CNNNBR value in the controller description. The threshold function may be turned off or changed in the threshold (THRESHOLD) parameter on the CRTLINASC command. To report the problem, start problem analysis (ANZPRB command).
Technical description . . . . . . . . : The length of the dialing digit has been found to be in error enough times to cause a threshold error.
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28
Message File : QCPFMSG