Ansicht
Dokumentation

CPI8ED7 - Frame received on line &23 rejected by network. ( OS/400 )

CPI8ED7 - Frame received on line &23 rejected by network. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8ED7
Frame received on line &23 rejected by network.

Message Long Text :

Cause . . . . . : This is a temporary condition; however, if your line is not operational, the probable causes are:
-- The X.25 network is not working correctly.
-- The I/O card Licensed Internal Code is not working correctly.
Recovery . . . : If line &23 is not operational, do one or more of the following:
-- Contact the X.25 network provider to verify that the X.25 network is operational.
-- If the problem continues, report the problem (ANZPRB command).
Technical description . . . . . . . . :
A high level data link control (HDLC) frame sent on line &23 had a sequence number that was not correct. The network rejected the frame in error, by transmitting an HDLC frame reject (FRMR) frame in response to a previously received frame. The Z-bit was set indicating that the network considered the sequence number of the received frame not correct (Nr count not valid).

- Processor Resource ....: &26
- Adapter Resource ......: &27

Message File : QCPFMSG
Library Message File : QSYS2924


Vendor Master (General Section)   Vendor Master (General Section)  
This documentation is copyright by IBM.