Ansicht
Dokumentation

CPI8F1F - Line &23 failed. ( OS/400 )

CPI8F1F - Line &23 failed. ( OS/400 )

Vendor Master (General Section)   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8F1F
Line &23 failed.

Message Long Text :

Cause . . . . . : The following may have caused the problem:
-- An error may have occurred in the network transceiver or the transceiver cable.
-- The I/O adapter card may be the cause of this error.
Recovery . . . : Vary the line off. Then disconnect the transceiver cable from the system. Reconnect the transceiver cable and vary the line on. If the problem persists, press F14 to run problem analysis and report the problem.
Technical description . . . . . . . . : The adapter detected a Signal Quality Error (SQE) condition. SQE is also known as the Heartbeat Signal.

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG