CPI8F5E - No cable was detected on port &28 of network interface &30. ( OS/400 )

CPI8F5E - No cable was detected on port &28 of network interface &30. ( OS/400 )

ROGBILLS - Synchronize billing plans   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8F5E
No cable was detected on port &28 of network interface &30.

Message Long Text :

Cause . . . . . : One of the following may have caused the problem:
-- The INTERFACE parameter value on the CRTNWIFR command is not compatible with the network cable that is installed.
-- The RSRCNAME parameter value on the CRTNWIFR command is not specified correctly.
-- The network cable is either not installed or not working correctly.
-- The communications adapter card is not working correctly.
Recovery . . . : Do one or more of the following:
-- Verify that the RSRCNAME and the INTERFACE parameter values on the CRTNWIFR command are correct.
-- If you had to attach or change your cable, you must load the I/O card Licensed Internal Code again. To do this, you must use the Vary Configuration (VRYCFG) command to vary off network interface &30. Then vary on network interface &30 with the RESET parameter (F10 to display additional parameters) specified as *YES.
-- If the problem continues, press F14 to run problem analysis and report the problem.
Technical description . . . . . . . . :

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924