Ansicht
Dokumentation

CPI8FCB - Line &23 failed during insertion into the token-ring network. ( OS/400 )

CPI8FCB - Line &23 failed during insertion into the token-ring network. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   Vendor Master (General Section)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI8FCB
Line &23 failed during insertion into the token-ring network.

Message Long Text :

Cause . . . . . : The following may have caused the problem:
-- The token-ring adapter card detected a failure during the insertion process into the token-ring network.
Recovery . . . : Vary off the line and vary it on using the vary configuration (VRYCFG) command with RESET (*YES) specified. If the problem persists, press F14 to run problem analysis.
Technical description . . . . . . . . : The token-ring adapter did not receive the necessary response(s) to the Request Parameters MAC frame from the token-ring LAN manager and/or the ring parameter server (RPS) required to attach to the ring.

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


TXBHW - Original Tax Base Amount in Local Currency   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.

Length: 3259 Date: 20240425 Time: 121346     sap01-206 ( 3 ms )