Ansicht
Dokumentation
CPI947C - Time-of-Day function has failed on IOP &26, IOP &26 is operational ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time Fill RESBD Structure from EBP Component StructureThis documentation is copyright by IBM.
Message : CPI947C
Time-of-Day function has failed on IOP &26, IOP &26 is operational
Message Long Text :
Cause . . . . . : The Time-of-day function on the IOP card has failed. The IOP can still operate but any timed power-on functions, automatic power-on restart and IPL-related time-of-day activities are not available.
Recovery . . . : The IOP is operational without the Time-of-Day function. It is necessary to manually enter the Time-of-Day using the system commands available. Card replacement is required to regain Time-of-Day function. F14 to run problem analysis.
Technical description . . . . . . . . : The error log ID is &22.
Message File : QCPFMSG
Library Message File : QSYS2924
ABAP Short Reference CL_GUI_FRONTEND_SERVICES - Frontend Services
This documentation is copyright by IBM.