CPI95BF - Incompatible media detected by Optical Library &25. ( OS/400 )
General Material Data rdisp/max_wprun_time - Maximum work process run timeThis documentation is copyright by IBM.
Message : CPI95BF
Incompatible media detected by Optical Library &25.
Message Long Text :
Cause . . . . . : This error was caused by an incompatible media being put into the Optical Library.
Recovery . . . : If the cartridge was added using the Add Optical Cartridge (ADDOPTCTG) command, it should have been returned to the Input/Output station.
If the cartridge was manually inserted into the library, it should be removed using the Remove Optical Cartridge (RMVOPTCTG) command. A reclaim of the internal optical volume table (RCLOPT) may be required before the cartridge can be removed.
Technical description . . . . . . . . :
- Reference Code . . . . . . . . . . : &33
- Error Log ID . . . . . . . . . . . : &22
- Device Resource Name . . . . . . . : &27
Message File : QCPFMSG
Library Message File : QSYS2924