CPIA08D - Journaling information for object &2 with file ID &1 destroyed. ( OS/400 )
ROGBILLS - Synchronize billing plans rdisp/max_wprun_time - Maximum work process run timeThis documentation is copyright by IBM.
Message : CPIA08D
Journaling information for object &2 with file ID &1 destroyed.
Message Long Text :
Cause . . . . . : Journaling information for this object was found to be damaged during the Reclaim Storage (RCLSTG) operation.
Recovery . . . : Perform one of the following:
1. Restore a previously saved version of the object. Then run the Apply Journaled Changes (APYJRNCHG) command to apply changes made to the object since its last save.
2. Restart journaling on the object with the Start Journal (STRJRN) command. Then save the object to preserve its journal attribute information.
Message File : QCPFMSG
Library Message File : QSYS2924