Ansicht
Dokumentation

CPIB464 - &2 cannot connect. TCP/IP interface not started for line &1. ( OS/400 )

CPIB464 - &2 cannot connect. TCP/IP interface not started for line &1. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPIB464
&2 cannot connect. TCP/IP interface not started for line &1.

Message Long Text :

Cause . . . . . : A TCP/IP supported work station &2 could not connect to the local system because the TCP/IP interface is not started for line &1 using Twinaxial Data Link Control (TDLC) support.
Recovery . . . : On the local system, do the following:
1) Display the active jobs on the system (WRKACTJOB command) and verify that TCP/IP is active (QTCPIP job).
2) If TCP/IP is not active, start TCP/IP (STRTCP command).
3) If TCP/IP is active, start the TCP/IP interface (STRTCPIFC command) for line &1.
Technical description . . . . . . . . : A TCP/IP supported work station &2 attempted to connect to the local system on line &1. The local system did not automatically start the TCP/IP interface for line &1. You must start the TCP/IP interface before the connection to the work station can continue.

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   CL_GUI_FRONTEND_SERVICES - Frontend Services  