CPPC014 - IDLC frame size configuration error on line &23, network interface &30. ( OS/400 )
Fill RESBD Structure from EBP Component Structure ABAP Short ReferenceThis documentation is copyright by IBM.
Message : CPPC014
IDLC frame size configuration error on line &23, network interface &30.
Message Long Text :
Cause . . . . . : The MAXFRAME parameter in the IDLC line or controller description exceeded the maximum established length.
Recovery . . . : Vary off the line. Reduce the size of the MAXFRAME parameter for the line or controller. Vary on the line again.
-- To change MAXFRAME for a line description use CHGLINIDLC.
-- To change MAXFRAME for a controller description use CHGCTLAPPC, CHGCTLHOST, or CHGCTLRWS.
Technical description . . . . . . . . :
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
Message File : QCPFMSG
Library Message File : QSYS2924