CPPC035 - *Attention* The adapter does not support the configured MAXFRAME value for line &23 ( OS/400 )

CPPC035 - *Attention* The adapter does not support the configured MAXFRAME value for line &23 ( OS/400 )

General Data in Customer Master   Vendor Master (General Section)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPPC035
*Attention* The adapter does not support the configured MAXFRAME value for line &23

Message Long Text :

Cause . . . . . : The following may have caused the problem:
-- The MAXFRAME value in the CRTLINETH command is too large.
Recovery . . . : Vary off the line. Use the CHGLINETH command to reduce the MAXFRAME value. Then vary the line back on.
If the problem persists, press F14 to report the problem to your Hardware Service Provider.

Technical description . . . . . . . . :
- Product Activity Log ID: &22
- Processor resource ....: &26
- Adapter resource ......: &27
- Line description .....: &23

Message File : QCPFMSG
Library Message File : QSYS2924


BAL Application Log Documentation   CL_GUI_FRONTEND_SERVICES - Frontend Services  