Ansicht
Dokumentation

FMT7262 - Data-field length exceeds header value. ( OS/400 )

FMT7262 - Data-field length exceeds header value. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   BAL_S_LOG - Application Log: Log header data  
This documentation is copyright by IBM.
SAP E-Book


Message : FMT7262
Data-field length exceeds header value.

Message Long Text :

Cause . . . . . : A SORTR or SORTRS job is being processed, and the data field specifications (F,D or F,S in columns 6 and 7) for this include set exceed the value in the header specification statement.
Recovery . . . : Correct the error. Run the job again.
Technical description . . . . . . . . : An error exists in either the output record length in the header specification or in the Start and End fields in the field description specification statements. If you are dropping the control field(s) (X in column 28 of the header specification statement), the data field length is the same as the output record length (columns 29 through 32 of the header specification). If you are not dropping the control field(s), the control field length must be subtracted from the output record length to determine the data-field length.

Message File : QFMTMSG
Library Message File : QSYS2924


CPI1466 during Backup   CPI1466 during Backup  
This documentation is copyright by IBM.