GLD017E - Pass-through bind failed on &1 for entry &2. ( OS/400 )
General Material Data General Data in Customer MasterThis documentation is copyright by IBM.
Message : GLD017E
Pass-through bind failed on &1 for entry &2.
Message Long Text :
Cause . . . . . : Pass-through authentication bind failed for specified entry using the given host and port.
Recovery . . . : This condition may occur when the user name or password is incorrect. Please verify following:
1. The pass-through directory server is running on the specified hostname and port number.
2. If attribute mapping is configured, then the password of the mapped DN on the pass-through directory matches the password supplied.
3. If the entry contains ibm-ptaLinkAttribute, it does not have the value _DISABLE_.
4. If attribute mapping is configured as "ibm-slapdPtaAttMapping: attr1 Å attr2", the entry contains attribute "attr1".
5. If attribute mapping is configured, the mapped entry must be present on the pass-through directory.
Message File : QGLDMSG
Library Message File : QSYS2924