Ansicht
Dokumentation

LNR7035 - Key or keys not correct in START statement &3 for file &8. ( OS/400 )

LNR7035 - Key or keys not correct in START statement &3 for file &8. ( OS/400 )

CL_GUI_FRONTEND_SERVICES - Frontend Services   PERFORM Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : LNR7035
Key or keys not correct in START statement &3 for file &8.

Message Long Text :

Cause . . . . . : The last key field specified in START statement &3 was reference modified; however, the starting position or the length of the reference modified key field was not correct. A starting position of &2 was expected; &1 was found. A maximum length of &9 was expected; &10 was found. Message issued at statement &3 of COBOL program &6 in program object &4 in library &5.
Recovery . . . : Change the starting position or the length of the reference modified key field. The starting position should be &2, and the maximum length of the key should be &9.

Message File : QLNRMSG
Library Message File : QSYS2924


CPI1466 during Backup   Fill RESBD Structure from EBP Component Structure  
This documentation is copyright by IBM.

Length: 3240 Date: 20240425 Time: 134910     sap01-206 ( 3 ms )