OPT6722 - Volume is write protected. ( OS/400 )
Addresses (Business Address Services) RFUMSV00 - Advance Return for Tax on Sales/PurchasesThis documentation is copyright by IBM.
Message : OPT6722
Volume is write protected.
Message Long Text :
Cause . . . . . : An operation which would result in a write being done to volume &1 was attempted. Volume &1 was found to be write protected.
Recovery . . . : A volume can be either logically or physically write protected. Ensure that the volume is physically write enabled by doing the following:
Remove the optical cartridge from the library and disable the write protection device on the cartridge. Add the cartridge to the same optical library and try the request again. If the cartridge is write enabled the cartridge has become logically write protected and can no longer be written to. This is usually the result of some type of media problem with the volume. The only write operation that is allowed once this happens is the initialize volume request. If you require the data on the volume be sure you first copy the volume before you attempt to re-initialize it.
Message File : QCPFMSG
Library Message File : QSYS2924
CPI1466 during Backup BAL Application Log Documentation