PLI1200 - UNDERFLOW condition raised at &4 in &3. ONCODE &1. ( OS/400 )

PLI1200 - UNDERFLOW condition raised at &4 in &3. ONCODE &1. ( OS/400 )

ROGBILLS - Synchronize billing plans   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : PLI1200
UNDERFLOW condition raised at &4 in &3. ONCODE &1.

Message Long Text :

Cause . . . . . : The value of the exponent from the floating point operation is too small for the format of the specified receiver. The exponent value must be greater than -127 for short format floating point, and greater than -1023 for long format floating point. Processing continues but the result will be unpredictable.
Recovery . . . : Change the value of the exponent or change the format of the receiver.

Message File : QPLIMSGE
Library Message File : QSYS2924