Ansicht
Dokumentation

PQT3603 - Connection with device &8 cannot be established. ( OS/400 )

PQT3603 - Connection with device &8 cannot be established. ( OS/400 )

ROGBILLS - Synchronize billing plans   PERFORM Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : PQT3603
Connection with device &8 cannot be established.

Message Long Text :

Cause . . . . . : A session cannot be established with the device at RMTLOCNAME &17, using PORT &18. The error code is &19. This indicates one of the following conditions:
10: The specified remote location name (RMTLOCNAME) was rejected.
15: The activation timer (ACTTMR) value configured for the device expired before the device was available.
19: The connection is not permitted.
22: The device did not respond to a connection request.
20-39: A communications failure occurred.
41-59: An internal failure occurred.
60: The device did not respond within the time specified by the Printer response timer.
Recovery . . . : Error code 10: Specify a correct remote location name. Verify that the IP address at the device and the remote location name in the printer device description for device &8 are the same.
Error code 15: Increase the value for ACTTMR in printer device description &8 (CHGDEVPRT) or determine if your network has a problem.
Error code 19: An exit program associated with exit point QIBM_QSO_CONNECT did not permit the connection. Change the exit program in order to allow the connection.
Error code 22: The device may not be able to accept a connection request because another writer is sending it data, it is in the process of ending a connection with another writer or it has errors. If the device has a connection with another writer or the device is in the process of ending a connection with another writer, then this is a normal error code. Otherwise, verify that the port number (PORT) specified for printer device description &8 matches the port number specified at the device. If these values match, you may need to reset the device before starting the writer. Refer to information in the following section on error codes 20-39. If the problem continues, report it using the ANZPRB command.
Error codes 20-39: Verify configuration values and check for problems in your network. Consider increasing the value specified for RETRY in the PSF configuration object (CHGPSFCFG) used with &8 (USRDFNOBJ). If a PSF configuration object is not in use, create one (CRTPSFCFG). Then specify it in the printer device description for &8 (CHGDEVPRT) using USRDFNOBJ. After correcting the problem, start the printer writer to begin processing files again. If the problem continues, report it using the ANZPRB command.
Error codes 41-59: Start the printer writer again. If the problem continues, report it using the ANZPRB command.
Error code 60: Consider increasing the value for Printer response timer in the PSF configuration object. You may also want to verify the status of the printer and the network.
Technical description . . . . . . . . : The internal message identifier (ID) is &6.

Message File : QPQMSGF
Library Message File : QSYS2924


Fill RESBD Structure from EBP Component Structure   ABAP Short Reference  
This documentation is copyright by IBM.

Length: 3258 Date: 20240329 Time: 094033     sap01-206 ( 3 ms )