Ansicht
Dokumentation
PQT4112 - Permanent hardware error on device &1. ( OS/400 )
Addresses (Business Address Services) CPI1466 during BackupThis documentation is copyright by IBM.
Message : PQT4112
Permanent hardware error on device &1.
Message Long Text :
Cause . . . . . : A permanent hardware error was detected on device &1. The sense data received from the printer was &2. Processing by the printer writer ended.
Recovery . . . : If locally attached, vary the controller off then on. If remotely attached, vary the line or controller off then on. Use the Work With Configuration Status (WRKCFGSTS command) to perform this operation. Then start the print writer again. If the problem continues, report it (ANZPRB command).
Message File : QPQMSGF
Library Message File : QSYS2924
General Material Data BAL Application Log Documentation
This documentation is copyright by IBM.
Length: 3220 Date: 20240425 Time: 114350 sap01-206 ( 3 ms )