Ansicht
Dokumentation
PWS0011 - Error occurred during character conversion. ( OS/400 )
General Material Data BAL Application Log DocumentationThis documentation is copyright by IBM.
Message : PWS0011
Error occurred during character conversion.
Message Long Text :
Cause . . . . . : Error type &3 occurred converting from client CCSID &1 to server CCSID &2. The error types and there meanings are:
1 -- The client or server CCSID is not a valid CCSID.
2 -- The client or server CCSID is 0 and is not allowed.
3 -- The client or server CCSID is 65535 and is not allowed.
4 -- Conversion results in data truncation.
5 -- Source string contains DBCS characters or data that is not valid.
6 -- A shift character that is not valid was found during mixed to single-byte conversion or mixed EBCDIC to mixed EBCDIC conversion.
8 -- No translation defined for CCSID &1 to CCSID &2.
9 -- Substitution characters were used but not allowed.
Other -- Internal error occurred during conversion.
Recovery . . . : The error was caused trying to convert either by a parameter value or data supplied by the client. Determine which item is in error and either change the CCSID or the data to correct the problem.
Message File : QIWSMSG
Library Message File : QSYS2924
Addresses (Business Address Services) ROGBILLS - Synchronize billing plans
This documentation is copyright by IBM.
Length: 3243 Date: 20240328 Time: 113604 sap01-206 ( 2 ms )