TCP7508 - Server API Datafilter directive does not have the correct number of procedures. ( OS/400 )
ABAP Short Reference CL_GUI_FRONTEND_SERVICES - Frontend ServicesThis documentation is copyright by IBM.
Message : TCP7508
Server API Datafilter directive does not have the correct number of procedures.
Message Long Text :
Cause . . . . . : The Server API Datafilter directive &1 requires open, write, and close procedures to be defined.
Recovery . . . : Use WRKHTTPCFG or the ADMIN Server Configuration and Administration page to update the Datafilter directive to contain the correct number of procedures.
Technical description . . . . . . . . : The syntax of the Datafilter directive should be of the form: Datafilter /QSYS.LIB/serverlib.LIB/serverpgm.SRVPGM:open:write:close, where serverlib is the name of the QSYS library and serverpgm is the name of the Server API service program.
Message File : QHTTPMSG
Library Message File : QSYS2924
CPI1466 during Backup General Material Data
This documentation is copyright by IBM.