Complete OS/400 Messages Documentation From CPF3708 up to CPF4601

Complete OS/400 Messages Documentation From CPF3708 up to CPF4601

This documentation is copyright by IBM.
Count: 1439 Skipped: 0
OS/400 Messages
Description
Save file &1 in &2 too small.
Tape devices do not support same densities.
Not all security objects saved to save file &3.
&4 owns &2 &1 in &3.
Not authorized to ALWOBJDIF parameter.
&2 &1 in library &3 not included.
Save storage operation did not complete successfully.
Restore of all system storage ended checksum protection.
File not restored. Object name conflict for file &1.
File not restored. Object type conflict for file &1.
File not restored. Date or time conflict for file &1.
RSTLIB command not valid for file &1.
RSTOBJ command not valid for file &1.
File not selected. Data encrypted or not valid.
File starts on a previous volume for file &1.
File not selected. File label or file name mismatch for file &1.
Restore command not valid for file &1.
Owner of &2 &1 in library &3 not found.
Not able to update QSAVSTG data area in library QSYS.
Error occurred during install of &2 &1.
Installation &2 &1 in &3 not found.
Library &1 not found on installation media.
Error occurred during Initialize System (INZSYS) processing.
&1 and &2 are the same for OBJ or USRPRF parameter.
Media error on volume &1.
Older version of &1 type &2 in &3 restored.
&4 owns &2 &1 in &3.
&2 &1 not selected to be restored.
&2 &1 not selected to be restored.
&2 &1 not selected to be restored.
Duplicate device &1 specified on device name list.
Device &1 specified with other devices.
Error decompressing file &6.
INZSYS or GO LICPGM currently running in another job.
Not all objects were saved.
Library &1 not restored to ASP &2.
Library &1 restored to ASP &3.
Library &1 restored to system ASP.
RSTASP parameter ignored for &2 &1.
Not authorized to &2 &1 in library &3.
Cannot use &2 &1 in library &3.
&2 &1 status error during restore operation.
&2 &1 in &3 previously damaged.
&2 &1 in &3 not restored.
Storage limit exceeded for user profile &1.
Authority not restored for user &4.
Save and restore data area &1 not found.
Device &1 used for save or restore is damaged.
Database file &1 member in &3 damaged.
&2 &1 restored to system ASP.
&2 &1 not restored to library &3.
&2 &1 restored to ASP &5.
&2 &1 restored to system ASP.
Library &1 not restored to ASP &2.
RSTASP parameter ignored for &2 &1.
Object &1 type &2 in &3 not found.
&2 &1 in &3 not saved.
Save and restore file on media is not complete.
File cannot be restored, displayed, or listed.
&2 &1 not restored to library &3.
No record of SAVLIB operation exists for &1.
System date and time earlier than reference date and time.
Object names cannot be specified with more than one library.
Object information for library &1 damaged.
Objects from library &2 not saved.
SAVFDTA(*YES) ignored. Not supported on previous release.
SAVFDTA(*YES) requires SAVF to be in different library.
No objects restored to ASP &2.
&2 &1 not restored to ASP &4.
&2 &1 not restored to ASP &4.
&1 specified more than once for OMITLIB parameter.
Library &1 description not restored.
Some libraries not saved.
No record of save operation exists for library &1.
(*SAVVOL) version of &2 &1 not restored to library &3.
&2 &1 not restored to library &3.
&2 &1 not restored to library &3.
&2 &1 not restored to &3.
&2 &1 not restored to &3.
&2 &1 not restored to &3.
User profile &1 not found.
Altered &2 &1 restored to library &3.
Attempted to save too many objects or database file members.
File not selected. Cannot restore from save type file &1.
Not authorized to save or restore &2 &1 in &3.
Cannot use &2 &1 in &3.
&2 &1 not restored to library &3.
&2 &1 in library &3 previously damaged.
&2 &1 in &3 not found.
&2 &1 in &3 not restored. Object not saved.
&2 &1 not restored to library &3.
Device &1 not found.
Device &1 not valid for command.
Data encrypted or not save data.
System must not be in manual mode.
File &1 not found.
Not all configuration objects saved to save file &3.
Not all configuration objects saved.
No objects saved or restored for library &1.
&1 objects saved from &3. &2 not saved.
SAVSYS completed. One or more objects not saved.
&1 objects restored. &2 not restored to &4.
&1 objects saved from &3. &2 not saved. &8 not included.
Not all user profiles or authority objects restored.
Not all user profiles had all authorities restored.
&1 libraries saved, &6 partially saved, &2 not saved.
Not all objects saved from all libraries.
&1 libraries restored; &4 partially restored; &2 not restored.
SAVSYSISD not complete for file &6.
No objects restored. &3 objects excluded.
&1 objects restored; &2 not restored; &6 excluded.
Save ended because of read error on internal system resource.
Not enough storage for save-while-active request.
Save ended. Unable to reach checkpoint.
Specified file for library &1 not found.
Library &1 not found.
File &1 in &2 not a save file.
Cannot determine VOL(*SAVVOL) location. No objects restored.
Restore device specified in the DEV parameter does not match VOL(*SAVVOL) device.
Not all subsystems ended.
&2 &1 not restored to &3.
No authorities to restore for user profile &1.
Only one library allowed with specified parameters.
Message queue not available.
Library &1 not created.
SAVACTMSGQ(*WRKSTN) not valid for batch job.
&2 &1 not restored to library &3.
Library &1 not saved.
&2 &1 in library &3 not restored.
No available space on diskette.
While processing &2 &1 in &3, encountered end of file &4.
Information not displayed. Error occurred.
Machine or ASP storage limit reached.
Save or restore operation ended unsuccessfully.
Error while processing &2 &1 in &3.
Storage limit exceeded for user profile &4.
Objects from library &3 not saved. Save limit exceeded.
Installation &2 &1 in &3 not found.
Errors occurred. Object not processed.
&2 &1 in &3 not saved.
Objects from save file &1 in &2 not restored.
&2 &1 was excluded.
&2 &1 in &3 not restored.
Not enough storage available to save library &1.
Save operation could not continue.
Cannot install from optical device &1.
Installation cannot be performed.
Data area &2 in &3 not available.
Signature verification failed for save file &1 in &2.
RSTASP &1 is not online.
Cannot perform signature verification.
FRCOBJCVN value not allowed.
Specified data compression not supported for device.
Specified data compression not supported for target release.
Information related to user profiles cannot be saved.
*NOCMTBDY not allowed with target release.
Library not allowed with *NOCMTBDY.
SPLFDTA not allowed with target release.
Not authorized to perform restore operation.
QDTA not allowed with target release.
User space &1 in &2 not valid.
PVTAUT not allowed with target release.
Work with licensed programs function not complete.
Not authorized to save private authorities.
Not authorized to restore private authorities.
Synchronization ID &1 in use.
Not authorized to RBDMFS parameter.
Synchronization ID &1 already started.
Synchronization ID &1 ended. Wait time exceeded.
Synchronization ID &1 ended. Save ended before checkpoint.
Synchronization ID &1 not started.
&2 objects completed. &3 objects deferred.
Not authorized to use DFRID.
Cannot save base operating system.
Service &1 with protocol &2 not found.
Save While Active synchronization manager bind error.
A communication error occurred.
Synchronization ID &1 ended. SAVACTWAIT error.
Synchronization ID &1 ended. Synchronization manager ended.
Synchronization session limit reached.
Library &1 not allowed in ASP &2.
Objects from save file &1 in &2 not restored.
Objects from save file &1 in &2 not restored.
Objects from save file &1 in &2 not restored.
Objects from save file &1 in &2 not restored.
Objects from save file &1 in &2 not restored.
Objects from save file &1 in &2 not restored.
Data decompression error for save file &1 in &2.
Save file &2 in &3 not complete.
Older version of &1 type &2 in &3 restored.
This message used internally only by SR.
Save cannot be completed at this time.
Library &1 not restored.
Save or restore of entire system completed unsuccessfully.
User profile &1 not restored. Not able to create UID or GID.
Cannot save sort table &1 to a release prior to V3R1M0.
Save file &1 not restored to library &3.
&2 &1 in &3 not restored.
Save file &1 in &2 in use.
&2 &1 not restored to library &3.
No objects from save file &1 in &2 saved to media.
Save file &1 in &2 too small for save operation.
&2 &1 not restored to library &3.
&1 type &2 not restored to library &3.
Starting library &1 not found.
Damaged object &2 &1 not restored.
Error occurred while attempting to access save file &1 in library &2.
No DLOs restored to ASP &1.
Cannot restore active sort table to the current release.
Values on CHGPERIOD parameter not valid.
Not authorized to ALWOBJDIF parameter.
Save file &1 cannot be processed by API QSRLSAVF.
&4 objects for &1 option &2 not restored.
&2 &1 in library &3 not restored.
*&2 &1 not restored to &3.
No objects saved or restored.
&2 &1 in &3 was restored with public authority of *EXCLUDE.
Duplicate names specified on the OBJ parameter.
*INCLUDE object required on OBJ parameter.
Option &1 not valid for object type &2.
Error occurred while attempting to use &1.
Specified parameter not valid for QSYS file system.
Specified parameter not valid for QDLS file system.
Parameters not valid with multiple file systems.
OBJ parameter value not valid for QSYS file system.
Specified parameter not valid for QSYS file system.
Specified parameter not valid for QDLS file system.
OBJ parameter value not valid for QDLS file system.
Function key 22 not valid on this field.
No objects saved on media file for specified subdirectory.
Specified value on DEV parameter not valid.
Too many values specified on the DEV parameter.
Tape devices do not support same densities.
&1 restored with public authority *EXCLUDE.
&1 objects saved. &2 not saved.
&1 objects saved. &2 objects not saved.
&1 objects restored. &2 not restored.
Save or restore ended unsuccessfully.
End of file &1.
Storage limit exceeded for user profile &1.
Cannot use &1.
&1 objects restored. &2 objects not restored.
Objects from save file &1 in &2 not restored.
Specified file for restore operation not found.
User profile &1 not allowed on the system.
Interactive section of user profile &1 not saved.
Interactive section of user profile &1 not restored.
Private authorities not restored for user profile &1.
Some authorities not restored for user profile &4.
Security changes occurred for &1 security objects.
User profile &1 not found on media.
&1 security or data format changes occurred.
&1 libraries had security or integrity changes.
Volume identifier &1 not valid.
Optical file specified not valid.
Error occurred during CCSID conversion.
Save or restore operation not allowed on ASP &1.
USEOPTBLK(*YES) not valid for CD-ROM premastering.
&2 &1 not restored to library &3.
Library &1 specified more than once for LIB parameter.
Public authority to &2 &1 in &3 revoked.
All authorizations to &2 &1 in library &3 revoked.
All authorizations to &2 &1 in library &3 revoked.
&2 &1 not restored to &3.
RSTAUT not allowed at this time.
&2 &1 in &3 restored. Object information not updated.
&2 &1 in &3 restored. Object information not updated.
Could not save object information for &2 &1 in &3.
Option 5 not valid for specified entry.
Object in use.
Incorrect level of save/restore index.
Vary off network servers option has conflicting values.
Cannot run this restore at this time.
Special authorities of *JOBCTL, *ALLOBJ and *IOSYSCFG required.
Save history for &2 &1 in &3 not updated.
&2 &1 in &3 restored. Object information not updated.
&2 &1 not restored to &3.
&2 &1 not restored to &3.
&2 &1 in &3 not restored.
File &1 not found in OBJ parameter list.
&1 already specified on the FILEMBR parameter.
Contents of FILEMBR parameter not correct.
FILEMBR specified but OBJTYPE must be *ALL or *FILE.
&1 on FILEMBR parameter not processed.
File not found.
Not able to save &1.
Not able to save &1.
Prestart job failed.
Not authorized to option.
Value in input data parameter not valid.
No files met FILEMBR selection criteria.
No objects saved or restored; &3 objects not included.
&1 objects restored. &2 not restored to &4.
Licensed program &1 option &2 release &4 not saved.
System name &1 also known as &2.
Licensed program &1 option &2 not deleted.
&2 &1 in &3 not saved or restored.
&2 &1 in &3 not allowed.
&2 &1 in &3 not saved.
&2 &1 not restored to &3.
No libraries or objects saved.
System library cannot be saved or restored.
Device resources not available.
Device &3 not available.
Devices not valid in media definition.
Error in media definition &1.
No language objects exist.
&2 &1 not restored to &3.
&2 &1 in &3 not found.
S/38 device configuration objects not restored.
Licensed program &1 option &2 not processed.
Device &1 is not a valid device.
&3 objects for product &1 option &2 release &4 not processed.
No licensed program information found for target release.
&2 &1 not restored to &3.
&2 &1 in &3 not saved.
Format not valid for *MEDDFN.
Optical file path name not valid.
Optical volume &1 not valid.
The RSTASP value specified cannot be used with this save media.
Not authorized to SECDTA(*PWDGRP) parameter.
Unexpected error code &1 received.
Mail objects for &2 &1 not restored.
&2 &1 in &3 not saved.
&2 &1 in &3 not saved.
Not all security objects saved.
Cancel reply received for message &1.
Error occurred during processing.
Tried to save too many office mail objects.
Interactive part of profile &1 not saved.
File found on media contains media file mismatch.
&2 &1 in library &3 not saved.
Wrong tape volume loaded on device &1.
Duplicate device name specified.
ObjectConnect internal error, function code &1, return code &2.
Volume is full on &1.
Optical device not allowed with other devices.
Trusted certificate list not available.
SAVASPDEV value not valid with this save media.
Not all digital certificate manager objects restored.
ASP device &1 not correct.
File &1 in &2 not valid with ASPDEV.
ASP device &1 not correct.
Error on the PATTERN parameter.
Only one library allowed with specified parameters.
SAVSYSINF completed. One or more objects not saved.
RSTSYSINF completed. One or more objects not restored.
Spooled file data key not valid.
PTF &1-&2 &3 not created.
Duplicate PTFs with identifier &1 found.
Cover letter not found.
Program call &1 &2 &3 not found.
Member not valid cover letter.
PTF information could not be saved or restored.
PTF &4-&5 not loaded.
Service command will not be processed.
Request made to end service job.
Context &7 previously deleted.
Context &7 data area not found.
Context &7 damaged.
Context &7 not available.
Service request canceled.
PTF &1-&2 &3 not found on specified device.
PTF not loaded.
Cannot open file &1.
Maximum number of problem log entries reached.
Program &1 not found.
Required programs not found. PTF incomplete.
Error occurred while processing PTFs during IPL.
Job being serviced ended during dump.
Job being serviced ended before trace started.
Already servicing another job.
Error occurred while saving APAR data.
CONTEXT(*MCHCTX) and TYPE(&4) cannot be used together.
CONTEXT(*MCHCTX) and OBJTYPE(*&6) cannot be used together.
Incorrect value specified for device parameter.
Records of PTF activity for licensed program are deleted.
Context damaged.
Library &7 not available.
Library &3 previously deleted.
Library &7 damaged.
Error message &2 received for file &1. Request ended.
File &1 cannot be overridden by file name &2.
Specified device contains a previously created APAR.
&1 version, release and modification level of library QSYS installed.
Library QSRV cannot be allocated.
Error occurred during PTF processing.
Not authorized to use exit program library &2.
Not authorized to use program &1 in library &2.
Value for DEV parameter incorrect.
Cannot send message &1 to QHST log stating function completed.
Error occurred during create APAR processing.
Dump not started because serviced job not running.
Dump not started because serviced job completed running.
Error during close of file &1. Output may not be complete.
Invalid directory type parameter value.
Invalid number of background jobs parameter value.
Bad return code from Licensed Internal Code &1.
File QPCSMPRT containing internal data not found.
PTF &1 found twice on the select list or the omit list.
One or more background jobs encountered an error or were canceled.
Error during creation or preparation of the output files or members.
Invalid background jobs' run priority parameter value.
Illegal use of program QSCDIRD2.
Invalid independent ASP number parameter value.
Object type &1 not permitted symbolic type.
No PTFs exist on save/restore media for licensed program &1 &2.
Delayed PTF &1-&2 not temporarily applied.
Delayed PTF &1-&2 not permanently applied.
Delayed PTF &1-&2 not temporarily removed.
Delayed PTF &1-&2 not permanently removed.
Error occurred while trying to call user exit program.
Trace storage full, trace ended.
Error occurred, trace ended.
STRCMNTRC completed successfully for &1 type &2
ENDCMNTRC completed successfully for &1 type &2
DLTCMNTRC completed successfully for &1 type &2
PRTCMNTRC completed successfully for &1 type &2
CHKCMNTRC completed successfully
Communications trace &1 type &2 has status &3
Storage could not be allocated
Trace storage not available in communications processor
Not authorized to communications trace service tool
Error occurred during communications trace function
Trace &1 type &2 already exists
Beginning or ending bytes exceeds maximum value
Total of beginning and ending bytes exceeds maximum value
&1 type &2 cannot be traced
Trace already ended.
Trace is ending - please wait
No communications traces exist.
Trace &1 type &2 does not exist
Trace data for &1 type &2 cannot be deleted
Trace &1 type &2 contains no data
Trace data for &1 type &2 cannot be printed
Communications trace data not printed
Communications trace function cannot be performed
Trace data for &1 type &2 cannot be printed
No SNA data found in trace &1 type &2
No trace records found for printing trace &1 type &2
Formatting options selected not valid
Communications trace data not printed
Communications trace print request cannot be completed
Network interface description &1 not found
No communications traces of type &1 exist
Remote IP address not valid.
Controller description &1 not found.
Controller description &1 not valid.
Number of user bytes to trace must be *CALC.
Trace &1 type &2 cannot be ended.
IP address not valid.
Job name *ALL and user *ALL not allowed
Not authorized to trace with generic job users.
STRTRC session ID &1 already exists.
ENDTRC session &1 already being ended by another job
Unexpected STRTRC failure, see low-level messages.
Trace session ID &1 not found.
Trace session ID &1, in library &2, data exists. Specify RPLDTA(*YES).
No active jobs found, STRTRC session not started.
Error occurred during processing of the PRTTRC command.
Error occurred during processing of the DLTTRC command.
DTAMBR &1 trace data not found in library &2.
Watch for event function cannot start. Reason code &1.
Limit exceeded for jobs watching for events.
Error occurred during processing of the program QTRCACT.
Unable to start/end the trace.
Another trace session is already active that specified RESTRIPL(*YES).
Another trace session is already active that specified JOINTRC(*YES).
Not authorized to set the trace characteristics of the specified jobs in a related job or thread.
Communications Trace operation failed.
Watch session &1 not found.
There is no active watch session for current user profile.
Session ID &1 already exists.
Specify Watch for message, LIC log entry or PAL entry.
No active jobs found, watch session not started.
The user does not have the required authority.
Invalid session identifier.
Not enough authority to watch operations.
*JOBCTL special authority required.
Value specified for watched job user name field is not valid.
Watched job name, watched job user name or watched job number field not valid.
Watch session &1 started by &2 command.
Relatonial operator &1 not valid.
&1 watch sessions ended. &2 not ended.
No watch sessions matching the &1 criteria.
Trace buffer size too large.
Cannot allocate library &1
Invalid Service tools user ID.
No more APAR data can be saved for this problem
Query of problem &1 failed
Problem record could not be created
Could not create user space in APAR library
Problem &1 could not be associated with an APAR library
Problem &1 &2 &3 in use
Problem &1 &2 &3 not found
Library &1 does not exist
Free
No APAR data restored from library &1
No APAR data associated with problem &1
SAVAPARDTA command can not be run
Queue entry ID &1 not valid.
&1 valid destinations and &2 duplicate destinations exist.
Distribution ID used for previous distribution.
No distributions exist on the agent queue.
Distribution cannot be sent.
Distribution ID not used.
Agent error occurred.
System error occurred.
Temporary server error occurred.
Distribution ID not valid.
Retriable system error occurred.
Interface error occurred.
Access ID &1 not valid.
More access IDs exist.
File server object not found.
Permanent server error occurred.
Location in file server object not valid.
File server object operation not valid.
File server object request not valid.
Limit of number of open file server objects exceeded.
End of data reached in file server object.
Cannot compress or decompress object &1 in &2.
Cannot compress or decompress file &1 in &2.
No objects compressed.
&1 objects compressed; &3 not compressed; &8 not included.
No objects decompressed.
&1 objects decompressed; &3 not decompressed; &8 not included.
&1KB storage reclaimed, &5 objects not processed.
Cannot allocate object &1 in &2.
Not all subsystems ended.
Compressed data for &1 in &2 type *&3 invalid.
Cannot compress object &1 in &2 type *&3.
Cannot compress object &1 in &2 type *&3.
No CPI-Communications calls were run. Trace ended.
Job is already being serviced or traced.
Trace already off.
Unexpected Trace CPI Communications error occurred.
Cannot deactivate trace, trace started from another job.
Internal system error has occurred.
Selected communications entry not valid.
Selected option not supported for communications method &5.
Communications side information object &1 already exists in library &2.
Communications side information object &1 not created in library &2.
Communications side information object &1 not changed in library &2.
*PROMPT value not allowed in batch mode.
BASETBL parameter not allowed with TBLTYPE(*SRTSEQ).
Parameter not allowed with TBLTYPE(*CVT).
Parameter allowed only if source file name is *PROMPT.
BASELANGID parameter not allowed.
CCSID not allowed with table type *CVT.
Sort sequence &1 not valid.
CCSID &1 outside of valid range.
Conversion from CCSID &1 to CCSID &2 is not supported.
Conversion from CCSID &1 to CCSID &2 is not defined.
CCSID &1 not supported.
Encoding scheme &1 of CCSID &2 not supported.
Language identifier &1 not valid.
DBCS data entered in a field that does not support DBCS entry.
One or more document profile fields contains invalid character data.
Truncate length not valid.
QLGSRTIO request control block field &1 is not valid.
Output data length parameter is not valid.
Type of request &1 is not valid at this time.
Sort already active.
No sort data specified.
QLGSORT request control block field &1 is not valid.
Key field &1 is not valid for key number &2.
Key size exceeds maximum.
Input file entry &3 field &4 is not valid.
Output file entry &3 field &4 is not valid.
No output files could be opened.
Sort internal storage limit exceeded.
Duplicate keys encountered for file &1 in library &2.
Sort sequence &1 not valid for UCS2 data.
CCSID &1 not supported by API.
Product not installed.
Invalid parameters for UCS-2 sort sequence table.
Locale object &1 not created.
Returned record feedback length not valid.
Message catalog &1 not created or updated.
Buffer information is not valid. Reason &1.
Value &1 for case request not valid.
Number of parameters, &1, entered for this API was not valid.
File &1 in library &2 or file entry &4 has error &3.
Value &1 for DBCS indicator not valid.
Value &1 for reserved field not valid.
User-defined table length &1 not valid.
Type of request &1 not valid.
Value &1 for reserved field not valid.
Requested function cannot be performed at this time.
Primary language not installed.
C or POSIX locale specified in the environment variable.
Sort sequence table specified or supplied is not valid.
Locale &1 does not exist.
Locale &1 is not a valid locale.
Locale not defined in environment variable.
Requested function is not available.
Path Type value is not valid.
Data in source file at line &1 is not correct
Error occurred retrieving information.
ENCODING SCHEME VALUE NOT CORRECT.
REQUEST TYPE NOT VALID.
CCSID REQUEST TYPE QUALIFIER NOT CORRECT.
Environment variables set to multiple locales.
Not all subsystems ended.
Sort heap space limit exceeded.
Required option &1 is not available.
User space &2 in library &1 not created.
User queue &1 not created.
User index &2 not created.
User space &1 not changed.
One or more errors found while trying to retrieve a pointer.
Information not retrieved from user space &1.
Error occurred while retrieving information from object &1.
Initial number of queue messages specified, &1, is not valid.
Extension parameter value &1 for queue overflow is not valid.
Value &1 for entry length parameter is not valid.
Value &1 for immediate update parameter is not valid.
Value &1 for key length parameter is not valid.
Value &1 for key insertion parameter is not valid.
Value &1 for the optimization parameter is not valid.
Value &1 for starting position parameter is not valid.
Value &1 for key length parameter is not valid.
Value &1 for maximum message size parameter is not valid.
Length of data is not valid.
Value &1 for force option is not valid.
Starting position &1 and length &2 cause space overflow.
New value &1 is shorter than the length specified.
Receiver area too small for length of data &1 specified.
Error occurred with input data parameter.
Pointer parameter is not on a 16-byte boundary.
Error occurred with receiver variable specified.
Object identifier not valid for lock type &1
Lock type &1 not valid for file attribute &2
Length specified in parameter &1 not valid.
Required parameter &1 omitted.
Pointer is not on a 16 byte boundary.
Error found by program &1.
Format name &1 is not valid.
Cannot get information about file &1.
Object &1 is not a file of the correct type.
Length of the receiver variable is not valid.
Value &1 for file override parameter is not valid.
File &1 has no members.
Cannot get information about member &3 from file &1.
Record format &3 in file &1 not found.
Object name &1 is not valid.
Value &1 for entry length attribute parameter is not valid.
Extended attribute &1 is not valid.
Value &1 for size parameter is not valid.
Value &1 for authority parameter is not valid.
Number of messages requested, &1, is too large for this queue.
Value &1 for queue type parameter not valid.
Library name &1 is not valid for output queue *ALL
Object type &1 is not valid.
User queue &1 in library &2 not restored.
Spooled file number &1 is not valid.
Value &1 for replace option is not valid.
Value &3 for parameter &2 not a valid name.
Number of parameters, &1, entered for this API was not valid.
Value for reserved field not valid.
Value for parameter &2 for API &1 not valid.
Value for parameter &2 for API &1 not valid.
Value for parameter &1 not valid.
Spooled file &4 not found.
More than one spooled file with same name.
User name or job number is not blank.
Internal job identifier is not valid.
Internal spooled file identifier is not valid.
Value &1 not valid for domain parameter.
Value &1 not valid for pointers parameter.
Pointers not valid for system domain user queue.
Operation not valid on system domain object.
Request for user domain object cannot be granted.
Value not valid for field &1.
Value not valid for field &1.
Value not valid for field &1.
Length &1 for key &2 not valid.
Value not valid for field &1.
Program &1 not created.
Internal job identifier not valid.
Internal job identifier no longer valid.
Job &3/&2/&1 not found.
Job &3/&2/&1 currently not available.
Job &3/&2/&1 does not exist.
Source file last changed date and time is not valid.
Not authorized to retrieve job information.
Job name specified is not valid
Internal identifier is not blanks and job name is not *INT.
Number of option template entries is not valid.
Option template entry is not valid.
Source file name and library is not valid.
Source file member is not valid.
Internal Representation of Program (IRP) string length parameter is not valid.
Program name and library is not valid.
Authority is not valid.
Source file library specified.
Source file member specified.
Source file last changed date and time specified.
Length of entries removed parameter is not valid.
Insert type &1 is not valid.
Number of entries &1 is not valid.
Error occurred with index entries parameter.
Entry is already in the index.
Error occurred with entry lengths and offsets parameter.
Length of lengths and offsets of entries &1 is not valid.
Remove type &1 is not valid.
Criteria length &1 is not valid.
Maximum number of entries &1 is not valid.
Search type &1 is not valid.
Length of index entries is not valid.
User index is full.
Remove or search information is not valid.
An exit program was not called in a multithreaded job.
Value for key &1 not valid.
Key &1 not valid for API &2.
Key &1 not allowed with value specified for key &2.
Key &1 required with value specified for key &2.
Value for key &1 not allowed with value for key &2.
Required key &1 not specified.
Key &1 allows one value with special value.
Number of variable length records &1 is not valid.
Key &1 specified more than once.
Literal value cannot be changed.
Value &1 not valid for transfer size request parameter.
Value &1 not valid for optimum space alignment parameter.
Value &1 not valid for usage tracking parameter.
Value &1 not valid for reclaim storage parameter.
Value &1 not valid for index size option parameter.
System pool &1 does not exist.
Pool size &1 is not valid.
Activity level &1 is not valid.
Pool &1 is not in use.
Changing machine pool activity level is not allowed.
Both pool size and activity level are required.
Message logging value &1 not valid.
List is too large for user space &1.
Value &1 for job status is not valid.
Value specified for job parameter is not valid.
Exit point &1 with format &2 already registered.
Exit point name &1 not valid.
Exit point format name &1 not valid.
Maximum number of exit programs reached for exit point &1 with format &2.
Exit point control &1 cannot be changed.
Length of exit program data &1 not valid.
Preprocessing exit program &1 library &2 with format &3 not valid.
Registration of exit point &1 with format &2 not performed.
Requested function cannot be performed at this time.
Registration facility repository not available for use.
Exit point &1 with format &2 does not exist.
&1 exit points deregistered. &2 exit points not deregistered.
Exit program number &1 does not exist.
Exit program name &1 library &2 not valid.
Exit program number &1 already assigned for exit point &2 with format &3.
Exit program number &1 not valid.
Continuation handle not valid.
Continuation handle no longer valid.
Comparison operator &1 not valid for selection criteria.
Exit point &1 with format &2 will not allow exit program &3 library &4 to be added.
Search criteria start position and length exceed boundary.
Number of selection criteria entries not valid.
Start position not valid.
Length of comparison data not valid.
Exit point &1 with format &2 will not allow exit program &3 to be removed.
No exit points found.
No exit programs found.
Exit program information not available.
Error occurred displaying exit points.
Error code parameter not valid.
Error(s) occurred during running of &1 API.
Severe error occurred during API processing. Reason code &1.
&1 option &2 not installed in job &7/&6/&5.
Licensed program install failed.
Not enough storage to install selected licensed programs.
Not enough auxiliary storage to continue installing licensed programs.
Not all PTFs processed for licensed program &1.
*LNG objects for licensed program &1 option &2 not installed.
PTFs for licensed program &1 not processed.
Attempted to use system program QLPCTLIN in QSYS.
Job queue QLPINSTALL in QSYS not found or in use.
Tape file &1 on volume &2 cannot be processed.
Tape file &1 on volume &2 cannot be processed.
Error occurred during install of &2 &1.
Secondary language &3 not installed.
Maximum number of save or restore operations exceeded.
*PGM objects for licensed program &1 option &2 not installed.
Cannot install library &1.
Errors occurred during the install process.
&4 objects for licensed program &1 option &2 not restored.
Error occurred with display.
Objects for product &1 option &2 release &4 not saved.
No product found in save file.
Exit program processing failed.
Objects for product &1 option &2 release &4 not restored.
Objects for product &1 option &2 release &4 not deleted.
Exit program processing found error in product.
The operating system cannot be used.
Error occurred setting secure sockets information.
Requested CD-ROM premastering state not valid.
Option &1 not valid.
Information about distribution set map not found.
Distribution set map identifier &1 is not valid.
optical file &1 on volume &2 cannot be processed.
Initialize System (INZSYS) message queue &1 in library &2 not found
Initialize System (INZSYS) in use.
The &1 parameter is not blank.
The &1 parameter is not 0.
CD-ROM size parameter &1 not valid
File will not fit on a CD-ROM.
Device &1 is not a valid installation device.
Cancel was selected for an inquiry message.
NLV language ID &1 is not valid.
Secondary language installation is not complete.
NLV language ID specified is the primary language ID.
Screen I/O parameter value is not valid.
Not authorized to the secondary language installation process.
Error occurred installing or deleting the BSAFE Licensed Internal Code.
Not authorized to work with installation profiles.
Installation profile &1 already exists.
Installation profile &1 is in use.
Installation profile &1 is damaged.
Not authorized to selected option.
Data in installation profile &1 not valid.
Installation profile &1 not found.
Value specified not valid.
Select only one installation profile from list.
File QALPAUTO in library QUSRSYS not found.
Overrides not allowed for installation profiles.
Installation profile must be specified.
Restore option must be 4.
Installation profile &1 not created.
Installation profiles not available.
Error occured while duplicating object &2 in library &3 type *&5.
Licensed programs not found on media.
Directory objects for product &1 option &2 release &4 failed to install.
Required user library cannot be installed.
Device parameter not allowed.
Errors occurred during prepare for install.
Release &1 does not match information found on system.
Upgrade from release &2 to release &1 is not valid.
Unexpected media error on device &1.
No licensed programs found on CD-ROMs.
Target release information is in use.
Information for release &3 not found on media.
Software agreement space is in use.
Attempted to use system program &1 in QSYS.
Incorrect parameter value.
Installation device &1 not found or cannot be used.
Installation profile is not valid or cannot be used.
Licensed program &1 option &2 requires selection of at least one other product.
&1 option &2 not available and requires removal of other products.
Required licensed programs not found on media.
*BASE product for selected option not available for preselection.
Automatic installation not complete.
Unable to accept software agreement.
Product identifier &1 option &2 not allowed.
Product option &2 not valid.
Software agreements have not been accepted.
Product identifier &1 not valid.
Internal error with installation profile &1.
Installation process ended. File system is not available.
Not authorized to accept software agreement.
Load source too small for release &1.
Not enough free space in the system ASP.
Allocate space for release value not valid.
Information not available for release &1.
Start space allocation parameter is not valid.
DDM parameter value not supported.
Application requester unable to support function requested.
Commitment control is not supported at target system &1.
Single-byte CCSID not supported.
Package binding process not active for specified SQL package.
Relational database &1 not found or not available.
Command not valid when package binding process is active.
An attempt to open an SQL cursor on a remote system failed.
Attempt to begin package binding process failed.
Resource limits exceeded.
Query not open.
Data type ID limit reached.
End relational database request not allowed.
Aliases can only be used when RMTLOCNAME(*IP) specifed.
Mixed byte or graphic data not supported.
COMMIT or ROLLBACK CL command not allowed.
Commitment control operation failed.
End relational database request failed.
Row or column too long.
Not authorized to access the relational database &1.
End relational database request in progress.
COMMIT or ROLLBACK failed on remote database
Commitment control operation failed.
DDM conversation path not found.
End relational database request failed.
Commit resulted in a rollback at the application server.
DDM data stream violates conversation capabilities.
Errors occurred starting DDM TCP/IP server.
Unable to start DRDA/DDM TCP/IP server.
DDM TCP/IP server error occurred processing client request.
An internal error was detected while processing a DRDA request.
Syntax error detected in DDM datastream.
The data descriptor received is not valid.
Relational database already accessed.
Data descriptor does not match data received.
DDM conversational protocol error was detected.
Relational database &4 not accessed.
Error occurred during distributed database processing.
Permanent error condition detected.
The SQL cursor had been previously opened at the remote system.
SQL cursor not open for an attempted remote operation.
Unexpected error occurred during SQL service dump processing. Reason code &1.
Relational database request ended by remote user.
Add relational database directory entry failed.
Change relational database directory entry failed.
Remove relational database directory entry failed.
Display relational database directory entry failed.
Work with relational database directory entry failed.
Display relational database directory entry failed due to an internal failure.
Change DDM TCP/IP attributes failed.
DDM conversation is either invalid or closed.
Unexpected internal DDM error.
Language identifier is not valid.
Country or region identifier is not valid.
Language identifier and country or region identifier are not valid.
Document Interchange Architecture language identifier is not valid.
Document Interchange Architecture country or region identifier is not valid.
Document Interchange Architecture language identifier and country or region identifier are not valid.
Value &1 for CCSID not valid.
Hardware Resource &1 not found.
Open of member &1 changed to CLEAR(NO).
Record length for file &1 on device &3 too long.
Record length specified is longer than record length of file &1.
One or more record formats exceed request unit size.
Block length for file &2 in &3 exceeds 8192.
Record length &7 for file &2 in library &3 too long.
Buffer length longer than record for member &1.
Unique keyed access path for member &1 not built.
Wait time &4 for member &1 not valid.
Unit of transfer &4 not valid. System default taken.
Force write ratio &4 for member &1 changed to &5.
Position open option ignored for member &1.
Select/omit error on field &4 member &1.
Error occurred while opening file or files.
Specified record length is not equal to record length of file.
Record format lengths exceed block length &7 for file &2 in &3.
Volume &5 on device &4 is density &6.
Error with device &4.
RCDBLKFMT(*&6) assumed for file &2 in &3.
Volume &5 on device &4 is code &6.
Open of member &1 was changed to SEQONLY(*NO).
Number of records per operation changed from &5 to &4.
Keyed sequence ignored for open of member &1.
Request to print page again starting at page &6, however, no page printed.
Request that file be held. No pages printed.
Processing not complete for volume &5 on device &4.
RCDLEN, BLKLEN, RCDBLKFMT, BUFOFSET values assumed.
The print operation is complete.
Print operation complete to the default printer device file.
Error occurred during print operation.
No device was identified for the print operation.
An error occurred during the print operation.
Print operation used default printer device file &6 library &7.
A function check was received while opening the print file.
Printer or device file not available.
Logon text not specified for file &2 in &3.
Error on diskette in device &4.
INDARA not matched between program and file &2 in library &3.
Keywords are not valid on device &4.
&6 lines per inch not supported on device &4.
&6 characters per inch not supported. Ten characters per inch used.
Size of member &1 increased &6 increments.
System abnormally ended the transaction with device &1.
System abnormally ended the transaction with device &4.
Internal object associated with device description &4 damaged.
Alternate volume identifier not standard.
Incorrect file expiration date &7 specified.
Systems Network Architecture error log received from device &6.
Systems Network Architecture error log sent to device &6.
Internal object associated with device description &1 damaged.
Incorrect user exit control value specified.
Record length &7 for file &2 in library &3 too long for device &4.
Open attributes not valid in a multithreaded job.
File &2 in library &3 not found or inline data file missing.
File &2 in library &3 with member &4 not found.
Device &4 not found while opening file &2 in library &3.
User not authorized to operation on file &2 in &3, member, device, or program device &4.
Device &4 not valid for file &2 in library &3.
Device &4 already open.
Error on device &4.
Media error on volume &8 device &4.
Device &4 cannot be assigned.
Error detected using program &6 in &7.
Volume acceptance response not valid.
End request specified by program &6.
Device &4 can not be used on this system.
Network interface &9 failed while opening file on device &4.
Cancel reply received for message &6.
Labels that are not valid were found on the volume.
DEVTYPE(*USERASCII) not allowed with externally-described file.
Wrong file label parameter specified.
File sequence number &7 not found on volume &6.
Device &4 cannot be opened because an error occurred.
No device defined for file &2 in library &3.
Record length exceeds the block length for file &2 in &3.
Device &4 was reset.
Device &4 cannot process loaded volume.
*REQUESTER device already used in different environment.
Shared open of member &4 not successful.
Remote location &5 for program device &4 is not correct.
Parameter integrity error occurred with reason code &1.
File &2 in library &3 did not print.
Device &4 reported a hardware failure.
Interface error while using device &4.
Switched connection failed for device &4 in file &2 in &3.
Open options ignored for shared open of member &3.
Error on device &4. response code is &6.
Open of member &3 file &1 in &2 failed.
Object not available for file &2.
Format selector program &6 in &7 not allowed.
Not able to allocate objects needed for file &2 in library &3 member or program device &4.
Record length &6 too large. Maximum length allowed is &7.
Value specified for &6 parameter is larger than &7 limit.
Error detected using program &1 in &2.
Cartridge &6 not found
Cartridge not available.
Category does not exist
Cartridge &6 not available.
Cannot open file &2 to device &4.
Level check on file &2 in library &3 with member &4.
File &2 in library &3 member &4 already open or has an error.
Option &7 not valid option for device &4.
Volume &6 on device &4 is protected.
Record format name for member &4 was not valid.
SNA 3270 API session cannot use SNUF device from earlier release.
Position option for member &4 not valid.
Page length &6 not valid for device &4.
Page width &6 not valid with current character per inch value or font value.
MSE not correct.
Library device error occurred
Level of program QSYS/QUSTAPEX not correct.
Synchronization level *COMMIT not supported in System/38 environment.
Synchronization level *COMMIT not supported in System/36 environment.
Specified user defined object &6 not valid. See previous messages.
File &6 not processed.
SNA protocol violation for data received for remote location &5, device description &4.
Negative response received for program device &4 in file &2, library &3.
Internal system failure for remote location &5, device description &4.
File sequence number &7 not correct for volume &6.
Systems Network Architecture session with device &4 abnormally ended.
Line &9 failed while opening a file on device &4.
Internal failure on device &4.
Too many devices specified for file &2 in library &3.
Session ended by a request from device &4.
No i5/OS licenses available. Try again later.
Device &4 function not successful.
Command not allowed
Database busy or error occurred
Library device &5 not ready
Library device storage slots full
Key mapping error for member &4.
Input file not a supported exchange type file.
Error opening member *ALL file &2 in &3.
Select/omit error for member &4.
Block length for file &2 in &3 exceeds BSC maximum of 8192.
A line or controller error has occurred.
File &2 in library &3 not a source file.
CTLCHAR(*FCFC) not valid for externally described file.
Cancel pressed at device &4.
Record length not valid for file &2 in &3 device &4.
*MOUNTED not correct.
Device list not correct.
No more cartridges to mount from category.
Device &4 cleaned.
Resource request timed out on device &4.
Timeout on device &4.
Program &6 in &7 not found.
Records in member &4 have duplicate keys.
Buffer length exceeded for file &2 in &3.
File &2 in &3 cannot be used with BLOCK(*IMG3270) or BLOCK(*DEF3270) specified.
Device can not support option specified for file.
Output queue &6 in &7 not found.
File &2 in &3 cannot be spooled.
Job cannot create any more spooled files.
Error on device or location &5 in file &2 in &3.
The device file does not contain an entry for screen size.
No device available.
Incorrect user exit control value specified.
Device &4 cannot process a block size of &7.
BLKLEN or RCDLEN not correct.
Sequence number too large for command.
Specified block length &5 not correct.
File &2 in library &3 already opened with TRMACCIN(YES) specified.
Cancel reply received for message &6.
Record length is less than 13 for file &1.
EOFDLY processing not valid for member &4.
OPNID(&4) for file &1 already exists.
Output only and MBR(*ALL) cannot be used together.
File &1 in &2 not a data base file.
Password or user ID not valid for request for remote location &5.
TERM-SELF, UNBIND, or NOTIFY received for remote location name &5, device description &4.
Establishment of a switched line connection failed.
Handling null capable fields is not valid for open of member &4.
File &2 in library &3 not opened.
Shared open of member &4 failed.
File level identifiers do not match.
Communications failure on device &1.
KEEP LOCKS option for member &4 is not valid.
SNA LU-SSCP session with &4 interrupted during logon.
Printer control specified not valid for file &2 in &3 containing GDF orders.
File &2 in library &3 member or device &4 not opened.
Input file record length is too large.
Incompatible open option for member &4 file &2 in library &3.
Input file contains a block length that is not valid.
Device &4 or location &5 in service mode.
Record length not valid for save file &2 in &3.
System failure on device &4.
Save file &2 in &3 already open.
Open of member &4 file &2 in &3 failed.
USEOPTBLK not correct with CD-Mastering.
Spool file availability control block is unavailable. Reason code &6.
Data conversion not supported.
Error on device &4.
No translation table address available.
Error on device &4. Device response code is &6.
Error on control unit &9 to which device &4 attached.
Member &4 can be opened only for input.
Commitment control not allowed for member &4.
Parameter specified not valid on SPLSCS keyword.
Error on device &4. Device response code is &6.
Open of member &1 changed to SEQONLY(*YES).
Access path for member &4 held.
Open of member &3 file &1 in &2 failed.
Incorrect image catalog name specified.
Data overwrite not allowed.
Invalid logical block identifier on device &4.
No more volumes to mount from catalog.
Virtual tape volume not available.
Virtual tape volume not found.
Device &4 is not available for use.
Constraints that are required to be verify prior to IPL have completed.
Device description &1 not valid for retail pass-through session.
Mode &7 specified for device &4 is not valid.
Member &4 cannot be opened while UPDPROD(*NO).
Internal failure occurred in query processor.
Shared open not allowed for query.
Page length in inches for file not valid on device.
Cannot open DDM file &2 in &3.
File &2 in &3 not opened.
File types for file &2 in library &3 are not compatible.
File &2 in &3 not opened.
File &2 not opened.
Page definition required for file &2 in library &3.
Page definition and form definition required for file &2.
Parameter not valid for retail pass-through for job &7/&8/&9.
Program name length &4 not valid for retail pass-through session.
File &2 in library &3 requests function not supported on device &4.
Last request to the device &4 failed.
Overflow line &6 for file &2 in library &3 not valid.
Sector size of input file not correct.
Hardware error on device &4.
Page width of &6 inches specified for file &2 in library &3 not valid.
Output queue &6 in &7 not available.
CHRID value detected on device &4 not valid.
Device description for device &4 partially damaged. VLOG-&8.
Error on file &2.
File &1 in library &2 is a DDM file.
Requester program device not valid for file &2 in library &3.
7.5 lines per inch not allowed for file &2 in library &3.
Record length exceeds block length of file &2 in &3.
Device &4 rejected the logon request.
SNA Bind command from host in error on device &4.
SNA bind error on device &4.
SNA session with device &4 ended abnormally. Device response code is &6.
Formatted logon text is not valid.
Negative response with sense data &7 received for remote location &5.
Logical damage on SQL view or materialized query table &1 in library &2.
S/36 program cannot open file to SNA 3270 API program device.
Input or output operations for member &4 not allowed.
Not able to open spooled file. Reason code is &6.
Not authorized to open member &4.
Default starting line number &6 beyond the page length.
INDARA mismatch between program and file &2 in library &3.
Device &4 dropped ready.
No authority to access data file sequence number &20.
REELS parameter &6 not correct for device &4.
Read backwards not valid for device &4.
File type does not match.
Not authorized to output queue &6 in &7.
Parameter not correct for device &4.
RCDBLKFMT *&7 not valid with code *&6 specified.
Arrival sequence not allowed for member &4.
File &2 in library &3 not opened.
File sequence number &6 already exists.
User buffer and blocked record input/output (I/O) are not valid together for file &2 in library &3.
i5/OS-ICF file support for file &2 in library &3 not available for program device &4.
Output queue for device &6 not found.
Not authorized to output queue for device &6.
Open failed waiting for program device &4 in file &2, library &3.
Entry not journaled for open of member &4.
Diskette in device &4 is write-protected.
Diskette exchanged during processing.
Device &4 equipment check.
Cannot open file &2 in &3.
Session not established for remote location &5, device description &4.
Line &9 failed when opening a file on device description &4, remote location &5.
Feedback code not recognized on device &4.
Parameter value IGCCPI for file &2 not valid.
Parameter value IGCSOSI for file &2 in library &3 not valid.
Error for remote location &5, device description &4.
Object &1 in &2 type *&3 not found.
Not authorized to object &1 in &2 type *&3.
User-defined function &5 cannot be invoked.
Function &5 cannot be run.
NEXT VALUE cannot be run.
Cannot allocate member &4 type *&3.
Member &4 saved with storage freed.
Not enough storage to perform query.
Error occurred during creation of temporary result.
Key mapping error for member &4.
Selection error for member &4.
Override or program parameter not allowed. Code &6.
Open options specified for query not allowed.
Query definition template &1 not valid.
Label &9 not found at sequence number &20.
CURRENT SERVER is not defined in the Relational Database Directory.
Input/output mapping cannot be performed. CCSID values not compatible.
Stacked updates not allowed.
Substitution characters may be used in data conversion.
Member &4 not opened for variable length record access.
Query exceeds specified time limit or storage limit.
Parameter &1 passed not correct.
File &2 in library &3 not opened.
Device &16 is in use in another job.
File &2 in &3 is not compatible with file &6 in &7.
Cannot add file sequence number &9 to full volume &6.
Device &16 has the wrong status.
Clear operation for member &4 failed.
Storage limit reached for member &4.
Program device &4 was not specified for file &2 in library &3.
Cannot send message to message queue.
Open of member &4 file &2 in &3 failed.
Field for member &4 not found in based-on file.
Open of member &4 file &2 in &3 failed.
Open of member &4 file &2 in &3 failed.
Open of member &3 file &1 in &2 failed.
Labels not found while processing file.
Switched line connection failed for file &2 in &3 on device &4.
Prestart job being ended.
Commitment control not valid for open of member &4.
Cannot produce spooled file.
&6 lines per inch not valid for file &2 in library &3.
&6 characters per inch is not valid for file &2 in library &3.
Value specified in UFCB (User File Control Block) is not valid at offset &1.
OPEN function ended for device or member &4.
Systems Network Architecture session with device &4 deactivated by device &4.
Cannot send message to message queue &1 in library &2.
Record separator &7 specified for file &2 in &3 not valid.
&7 cannot be used with file &2 in &3.
Not able to assign object &7 in &8 type *&9.
Combination of punch and printer type devices not valid.
REELS &6 not valid for output file &2 in &3.
Read backwards not valid for file &2 in &3.
Record block format *&6 not correct.
Buffer offset &7 not valid for file &2 in &3.
RCDLEN or BLKLEN or both required for file &2 in &3.
Block length &6 not valid for file &2 in &3.
Record length &7 not valid for file &2 in &3.
Record length &7 not valid with block length &8.
Block length less than minimum possible &7.
Device &4 no longer in ready status.
Volume loaded on device &4 is write protected.
Error detected using program &6 in &7.
Sequence number *END not valid.
Sequence number &6 not valid for REELS(*NS).
Open option for file &2 in library &3 for device &4 not valid.
Internal object associated with device description &4 damaged.
Error recovery not done for file &2 in library &3 for device &4.
Commitment definition &6 not valid for open of &4.
Commitment control resource limit exceeded.
Member &4 not journaled to journal &6.
Cannot associate journal &6 with commitment definition &9.
Open not allowed under commitment control; reason code &8.
No available device found.
Session start request failed for file &2 in library &3 for device &4.
Cannot start save or restore operation.
Page width &6 is not valid for file &2 in library &3.
Print quality value &6 not supported on device &4.
Paper source drawer &6 not supported on device &4.
Font identifier &6 not supported on device &4.
FORMFEED parameter not valid for file &2 in library &3.
Unable to update query options file.
FONT(*DEVD) not allowed for file &2 in library &3.
&6 program devices not added to file &2 in library &3.
Second open to file &2 in library &3 not allowed.
Remote format processing not permitted for file &2 in &3 on device &4.
*RECID processing not valid for file &2 in library &3 for program device &4.
FMTSLT(*RMTFMT) not valid for file &2 in library &3 for device &4.
CNVTYPE file parameter not valid for file &2 in library &3 for device &4.
CNVTYPE file parameter not valid for file &2 in library &3 for device &4.
CTLCHAR(*FCFC) specified with printer text functions.
Device &4 for file &2 in &3 in online test.
Error recovery for program device &4 canceled during open.
OUTPTY value &6 exceeds priority limit for user &7.
Tape devices do not support same densities.
CNVTYPE(*SRCPGM) not valid for source programs.
Remote location was not specified for program device &4.
Remote location &16 for program device &4 was not found.
User file control block is not valid.
*REQUESTER device is not available.
Error occurred while finding remote location for program device &4.
Record format for file &1 in &2 does not match model file.
&1 can not be specified on the OUTFILE parameter.
Job &4 is already being monitored.
Job &1 is not being monitored.
Job &1 user &2 job number &3 is not active.
Error occurred while finding location for program device &4.
Tape device &4 is not operational.
Load failure encountered on device &4.
End of media on device &4.
System cannot automatically select an APPC device description for the remote location.
Class-of-service for device &4 not valid.
OUTQ(*DEV) not allowed for spooled diskette files.
Open attributes not valid in a multithreaded job.
Cannot open file as SHARE(*NO)
Error extracting IDDU format &3.
Queried file format in access plan has changed.
Get option not valid for member &4.
Query request not completed. Library &1 in use.
User &1 not authorized to file &2 in &3.
Data mapping error from INSTEAD OF trigger on view &1. Reason code &5.
Format of diskette in device &4 is not supported.
Direct input/output (I/O) operation not valid.
Field outlining was not supported for DEVTYPE(*IPDS).
Error on device printing the output.
File &2 in &3 not opened.
Sequence number *NEXT was not valid.
Permanent I/O error on volume &9 in device &4.
File &2 in &3 not opened.
Job &1 specified on ENDDBMON command is not unique.
Address specified on FTRINTNETA parameter is not valid.
*JOBCTL special authority or QIBM_DB_SQLADM Function usage is required.
*JOBCTL special authority, QIBM_DB_SQLADM or QIBM_DB_SYSMON Function usage is required.
End of volume detected for file &2.
Alternate volume identifier not standard.
Input records from device &4 present in internal buffers. These records are ignored.
File &1 was already closed, never opened or not from this process.
Errors occurred while closing files.
File &2 in library &3 already temporarily closed.
File closed to device &4. GET with NOWAIT canceled.
File &2 in library &3 closed, device &4 may be unusable.
Temporary close for file &2 in library &3 changed to permanent close.
Print pages starting at page &6 requested again for file &2 in &3 on device &4.
Request to hold file &2 in library &3 on device &4.
Device &4 reported a hardware failure.
Cancel reply received for message &6.
SNA session with device &4 ended abnormally.
An Input or Output error detected on device &4.
Error on diskette in device &4.
Parameter integrity error occurred with reason code &1.
Communications failure on device &1.
Feedback code not recognized on device &4.
Error detected using program &6 in &7.
Volume acceptance response not valid.
End request specified by program &6.
Device &4 can not be assigned to system.
Network interface &9 failed while closing file on device &4.
Cartridge not in an available category
File &2 in library &3 member or device &4 was not closed.
Device &4 function not successful.
SNA bind command from host in error on device &4.
Timeout on device &4.
File &2 in library &3 not temporarily closed because file shared.
Device no longer in ready status.
Print buffer overrun on device &4.
Error on device &4.
Member &3 file &1 not closed.
Command not allowed
Database busy or error occurred
Library device &5 not ready
Library device storage slots full
Error detected while converting file &2 to AFPDS.
No file open with identifier &4.
Systems Network Architecture LU-SSCP session with device &4 interrupted during logoff.
Records not added to file &2 in &3.
Error on device &4. Device response code is &6.
Invalid record for output operation to save file &2 in &3.
Error on control unit &9 to which device &4 attached.
Error on device &4. Device response code is &6.
Cannot close DDM file &2 in &3 member &4.
Records not added to file &2 in &3.
Error occurred during processing of close operation. Close completed using the defaults.
Cancel pressed at device &4.
Data overwrite not allowed.
Error on device &4. Device response code is &6.
Tape device &4 is not operational.
Load failure on device &4.
End of media on device &4.
Invalid logical block identifier on device &4.
Session stopped by request from device &4. Probable device error.
Device &4 dropped ready.
MODLUD reset ended request. Internal failure in system.
Line &9 failed while closing the file on the device &4.
Labels found on volume &6 are not valid.
Interface error while using device &4.
Device &4 is not ready.
Permanent I/O error on volume &9 in device &4.
Format of diskette in device &4 is not supported.
Last request to device &4 failed. See message &7.
System cannot open device &4 because an error occurred.
Cannot send message to message queue.
Error on file &2 in library &3 device &4.
Line &9 failed while closing the file on the device description &4.
Volume on device &4 is write protected.
Program &6 in library &7 ended in error.
&6 records in buffer not valid for file.
Not able to allocate object &7 in &8 type *&9.
Temporary close not supported for file &2 in &3.
Device &4 may have lost data.
Error on device &4 in file &2 in &3.
Device &4 rejected logoff request with negative response &6.
Media error on volume &8 on device &4.
Device response code is &6.
&6 records lost when member &4 closed.
SNA session with device &4 ended abnormally. Device code &6.
Device &4 discarded received data.
Device &4 sent SNA data flow control(DFC) command that is not valid.
Data cancelled by device &4.
Error on device &4 in file &2 in &3.
Hardware error on device &4.
Transmit not allowed until previous response received.
Session reset ended request to device &4.
Device &4 cannot process loaded volume.
Hardware error on device &4.
Systems network architecture bind error on device &4.
Data sent to device &4 is not valid.
SNA session with device &4 end abnormally by device &4.
Close or suspend operation not allowed for file &2 in &3 on device &4.
Device &4 was reset.
Diskette in device &4 is write-protected.
Diskette changed during processing.
Device &4 equipment check.

Length: 279433 Date: 20210125 Time: 201815

Count: 1439     sap01-206 ( 1297 ms ) This documentation is copyright by IBM.