Ansicht
Dokumentation
EHSHEX01 - EHS_OH: Test Results for New Examination Categories
BAL Application Log Documentation CL_GUI_FRONTEND_SERVICES - Frontend ServicesThis documentation is copyright by SAP AG.
Overview
Different examination categories are available in the Medical Service component of EH&S Occupational Health.
At present the standard system contains the following examination categories:
- Audiogram
- Laboratory
- Physical
- Pulmonary function
These examination categories are usually all you need to represent the necessary medical examinations and tests in the system.
This enhancement gives you the option of defining additional examination categories if you require them.
The enhancement is made up of seven function module exits and one screen exit.
Parameters
Enhancement EHSHEX01 contains the following components:
- Function module exits:
- EXIT_SAPLEHS00AMBTAET_NEU_001: Transfers the header data for the called examination, loads the corresponding data into internal tables, and sends the screen number of the user-defined subscreen to the main program.
- EXIT_SAPLEHS00AMBTAET_NEU_002: Transfers the OK code from the main program.
- EXIT_SAPLEHS00AMBTAET_NEU_003: Supplies the indicator for registering a data change on the user-defined subscreen.
- EXIT_SAPLEHS00AMBTAET_NEU_004: Calls a user-defined detail screen.
- EXIT_SAPLEHS00AMBTAET_NEU_005: If the request to save the data is rejected, this exit resets the user-defined internal tables when changing to the display mode.
- EXIT_SAPLEHS00AMBTAET_NEU_006: Depending on the action indicator, medical tests in (internal) tables are created, deleted, initialized, or filled with data by means of an import program. Can also lock table entries.
- EXIT_SAPLEHS00AMBTAET_NEU_007: Creates medical tests in the corresponding database tables when a medical service is opened.
- Screen exit:
- SAPLXEHS00EXAMEXIT: The subscreen belonging to the examination category is created
in function group SAPLXEHS00EXAMEXIT. The number is freely definable and is transferred to function module EXIT_SAPLEHS00AMBTAET_NEU_001.
- The screen exit is called at the PBO or PAI time for subscreen '2579' of function group SAPLEHS00AMBTAET_NEU.
Procedure
To create your own examination categories, proceed as follows:
-
In the Implementation Guide for Occupational Health, choose
Specify Examination Categories and add the key and
description for the new examination category. For the key, use your namespace '5_' to '9_' (for example: '91' "Laboratory - Customer").
-
Create a transparent table in the customer namespace of the Data Dictionary. This table must have the
same key fields as the tables T7EHS00_EXA_LAB, T7EHS00_EXA_PHY, T7EHS00_EXA_PUL, and T7EHS00_EXA_AUD.
The 'TEST_NO' key field is used to differentiate between several medical tests in one examination (in laboratory tests, for example), and can be ignored if your examination does not need this sub-classification.
-
In addition to this tranparent table, you can create a structure in which you use '.include "Tabname"'
to include the fields and to define any additional fields that you want to display on the subscreen (for example, see EHS00S_EXA_LAB for the laboratory test).
-
Create the subscreen in the X function group XEHS00EXAMEXIT. To set up your subscreen in Screen Painter,
use the structure given above. The function module EXIT_SAPLEHS00AMBTAET_NEU_001 then also transfers
the parameter EXAM_MODE. This parameter contains the value 'C' if the screen fields are meant to be
changeable; if not, the value is 'D'. In the PBO of your subscreen, use LOOP AT SCREEN and the modification groups to set the input status of the input fields accordingly.
-
In the flow logic of your subscreen, program the following:
- The SELECT for the data from the database (use the function module EXIT_SAPLEHS00AMBTAET_NEU_001 to get the key for the WHERE condition).
- Data processing by means of internal tables and work areas.
- If required, processing of the OK code that is supplied with function module EXIT_SAPLEHS00AMBTAET_NEU_002
(for scrolling, sorting or searching in the user-defined subscreen, or for navigating in a user-defined detail screen).
- Navigation in a user-defined detail screen by double-clicking or using radio buttons. For this,
the OK code is transferred with function module EXIT_SAPLEHS00AMBTAET_NEU_002 to the user-defined program,
so that the relevant internal tables and work areas can be filled. The screen number for the detail screen is also set. The detail screen is called by function module EXIT_SAPLEHS00AMBTAET_NEU_004.
- Storage of the data in the database by means of a FORM routine with the addition 'ON COMMIT'. This FORM routine is executed if a 'COMMIT WORK' is called in the main program. If the data on your subscreen has been changed, use the function module EXIT_SAPLEHS00AMBTAET_NEU_003 to set the parameter UPDATE_FLAG = 'X'. If you set this indicator, a query about saving the data appears on the screen when you exit from the program
- If you answer 'No' to the query to save, this calls a 'ROLLBACK WORK' in the main program. All change indicators are initialized, and all changes in the internal tables and work areas are cancelled. You can use the function module EXIT_SAPLEHS00AMBTAET_NEU_005 to reset this data in a user-defined program.
-
If you are adding an examination to the main program, the tests belonging to this examination must be
selected from the database and appended to the corresponding internal tables when you call the user-defined
subscreen. As long as you do not save your data, the new examination can still be deleted from the main
program. Function module EXIT_SAPLEHS00AMBTAET_NEU_006 can also be used to delete the tests for the examination from the internal tables.
You can use the function group SAPLEHS00_MEDTESTS as a template for the steps described above. This
function group contains the controls for the examination types delivered with the standard system. It also uses the same interfaces.
-
Activate your project.
Note:
For information on the procedure for using enhancements, call the enhancement transaction CMOD and choose Utilities -> Online manual.
For more information, see BC - Basis → ABAP Workbench → BC - Changing the SAP Standard, as well as the documentation on the individual function modules for this customer exit.
rdisp/max_wprun_time - Maximum work process run time Fill RESBD Structure from EBP Component Structure
This documentation is copyright by SAP AG.
Length: 8311 Date: 20240419 Time: 122518 sap01-206 ( 134 ms )