Ansicht
Dokumentation

CPA570C - Call to controller &24 failed. Too many dialing digits. (C R) ( OS/400 )

CPA570C - Call to controller &24 failed. Too many dialing digits. (C R) ( OS/400 )

General Material Data   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPA570C
Call to controller &24 failed. Too many dialing digits. (C R)

Message Long Text :

Cause . . . . . : If an automatic calling unit is being used, the remote system answered the call before the local system had finished dialing.
If the modem is dialing, the number of dialing digits exceeded an internal limit.
Recovery . . . : Do one or more of the following:
-- Use the Work with Controller Description (WRKCTLD) command to ensure that there are not too many dialing digits in the connection number (CNNNBR parameter) in controller description &24.
-- Use the Work with Line Description (WRKLIND) command to ensure that there are not too many dialing digits in the calling number (CALLNBR parameter) in line description &23.
-- Power off the automatic calling unit or modem, then power on.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel recovery and inform any applications that are waiting for an operation that the recovery has been canceled.
R -- Try the operation one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The error code is &40: If V.25bis is being used, the total number o f CNNNBR and CALLNBR characters is too large. If V.25 is being used, the input/output processor (IOP) detected the distant station connected signal before all of the dialing digits were sent to the automatic calling unit.

Message File : QCPFMSG
Library Message File : QSYS2924


TXBHW - Original Tax Base Amount in Local Currency   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.

Length: 3261 Date: 20240420 Time: 162616     sap01-206 ( 3 ms )