We are hiring and constantly growing! Have a look through our vacancies to find the right role for you!

CPD401A - Could not establish SNMP communications with device &1. ( OS/400 )

CPD401A - Could not establish SNMP communications with device &1. ( OS/400 )

PERFORM Short Reference   Addresses (Business Address Services)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD401A
Could not establish SNMP communications with device &1.

Message Long Text :

Cause . . . . . : Was not able to establish SNMP communications with device &1. The reason code is &2. The reason codes and their meanings are as follows:
1 - The device appears to be an SNMP device but not a printer.
2 - The device appears to be an SNMP device but does not support the required level of an industry standard SNMP protocol.
3 - Communication with the device timed out. This could occur because of heavy network traffic, the device is not an SNMP device, or the read community name set on the device is different than expected.
Recovery . . . : Make sure that the device is a printer that supports the industry standard SNMP protocol and that the read community name is set correctly. Then try the operation again.

Message File : QCPFMSG
Library Message File : QSYS2924


ABAP Short Reference   Vendor Master (General Section)  
This documentation is copyright by IBM.

Length: 3243 Date: 20201022 Time: 051437     sap01-206 ( 2 ms )