CPD4305 - I/O attribute &1 field &2 format &3 not valid. ( OS/400 )
General Material Data RFUMSV00 - Advance Return for Tax on Sales/PurchasesThis documentation is copyright by IBM.
Message : CPD4305
I/O attribute &1 field &2 format &3 not valid.
Message Long Text :
Cause . . . . . : One of the following occurred:
-- The input/output (I/O) attribute specified for field &2 was not specified as 1) input only, 2) input and output, or 3) neither input nor output.
-- The field &2 is a derived field, a variable field, or a field mapped from a previous field in the query format. In these cases, the I/O attribute of the field was not specified as either 1) input only or 2) neither input nor output.
-- This is a join query, group by query, set operator (UNION, EXCEPT, or INTERSECT) query, distinct query, no duplicate keys query, or a subquery. In these cases, the I/O attribute of the field was not specified as either 1) input only or 2) neither input nor output.
Recovery . . . : The field &2 must have a valid I/O attribute of 1) input only, 2) input and output, or 3) neither input nor output. Change the field's attribute to be one of these valid I/O attributes. Input and output is not a valid I/O attribute for the following cases:
-- The field &2 is a derived field, a variable field, or a field mapped from a previous field in the query format.
-- This is a join query, group by query, set operator query, distinct query, no duplicate keys query, or a subquery.
Message File : QCPFMSG
Library Message File : QSYS2924
Vendor Master (General Section) ROGBILLS - Synchronize billing plans
This documentation is copyright by IBM.
Length: 3238 Date: 20240425 Time: 085345 sap01-206 ( 3 ms )