Ansicht
Dokumentation
QRY2216 - Test value must be the same between two files. ( OS/400 )
BAL Application Log Documentation CL_GUI_FRONTEND_SERVICES - Frontend ServicesThis documentation is copyright by IBM.
Message : QRY2216
Test value must be the same between two files.
Message Long Text :
Cause . . . . . : This query is using a matched primary join or unmatched primary join type (option 2 or 3 on the Specify Type of Join display). The comparison containing the test that is different from the first comparison between these two file IDs is shown in reverse image.
If multiple comparisons are specified between the same pair of file IDs, all of the comparisons must use the EQ test. If a test other than EQ is used, only one comparison is allowed between the pair of file IDs.
Recovery . . . : Use the EQ test for all comparisons, or specify only one comparison between these two file IDs. You may use the Select Records display for additional comparisons.
Message File : QQRYMSG
Library Message File : QSYS2924
General Data in Customer Master ROGBILLS - Synchronize billing plans
This documentation is copyright by IBM.
Length: 3230 Date: 20240328 Time: 185502 sap01-206 ( 2 ms )