Ansicht
Dokumentation

gw/startup - File read during startup to start external server

gw/startup - File read during startup to start external server

General Material Data   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
Diese Dokumentation steht unter dem Copyright der SAP AG.
SAP E-Book
------------------------------------------------------------------------
| Parameter : gw/startup |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Kurzbeschreibung : file read during startup to start external serve |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Parameterbeschreibung : |
| ----------------------- |
| Diese Datei wird während des Startes des Gateways gelesen, um |
| CPIC/RFC-Server zu starten die sich am Gateway registrieren sollen. |
| |
| Syntax |
| ====== |
| Die Datei wird folgendermaßen interpretiert : |
| |
| lokales Anstarten von Programmen |
| local programm [parameter ...] |
| |
| entferntes Anstarten von Programmen |
| hostname programm [parameter ...] |
| |
| Als Kommentarzeichen können ";*!" benutzt werden. Die einzelnen |
| Parameter in der Datei müssen durch Tabulatoren getrennt sein |
| |
| Beispiel : |
| ========== |
| Unter NT müssen die Optionen ( beginnen mit '-' ) |
| oder Strings die ein '/' enthalten in Anführungszeichen |
| gesetzt werden |
| |
| z.B. local "/priv/cpict2" "-tp" cpict2 "-gwhost" p29290 "-gwserv" |
| sapgw53 |
| |
| lokales Programm anstarten |
| |
| local /usr/sap/PRD/SYS/exe/run/cpicserver -tp cpicsrv -gwhost uw1033 |
| -gwserv sapgw53 |
| |
| lokal Programm anstarten und Überwachung vom Gateway einschalten |
| diese Überwachung wird mittels dem Schlüsselwort GWCHECK |
| eingeschaltet. Falls das Programm sich beendet wird es vom |
| Gateway nachgestartet. |
| |
| Diese Prüfung wird maximal alle %%gw/max_sleep%% Sekunden durch- |
| geführt. |
| |
| local GWCHECK /usr/sap/PRD/SYS/exe/run/cpicserver -tp cpicsrv |
| -gwhost uw103 -gwserv sapgw53 |
| |
| entferntes Programm auf dem Rechner hw1439 anstarten |
| |
| hw1439 /usr/sap/PRD/SYS/exe/run/rfcserver -tp rfcsrv -gwhost uw1033 |
| -gwserv sapgw53 |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Arbeitsgebiet : Gateway |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Einheit : Dateiname |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Defaultwert : gwstartup |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Wer darf ändern : Kunde |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Einschränkungen bei den Betriebssystemen : keine |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Einschränkungen bei den Datenbanksystemen : keine |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Sind andere Parameter betroffen oder abhängig : %%FN_GWSTARTUP%% |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Gültige Eingaben,Formate,Bereiche : Dateiname |
------------------------------------------------------------------------


------------------------------------------------------------------------
| Short Description : File read during startup to start external server
------------------------------------------------------------------------

------------------------------------------------------------------------
| Applications Area : Gateway
------------------------------------------------------------------------

------------------------------------------------------------------------
| Parameter Type : F
------------------------------------------------------------------------

------------------------------------------------------------------------
| Changes allowed : X
------------------------------------------------------------------------

------------------------------------------------------------------------
| Valid for Operating System : *
------------------------------------------------------------------------

------------------------------------------------------------------------
| Dynamic switchable :
------------------------------------------------------------------------

------------------------------------------------------------------------
| Same on all Servers :
------------------------------------------------------------------------


BAL Application Log Documentation   PERFORM Short Reference  
Diese Dokumentation steht unter dem Copyright der SAP AG.

Length: 7666 Date: 20240426 Time: 202258     sap01-206 ( 6 ms )