Ansicht
Dokumentation
PFR9116 - *LGLDBIO only valid when *JOBTYPE specified for DATATYPE parameter ( OS/400 )
General Data in Customer Master Fill RESBD Structure from EBP Component StructureDiese Dokumentation steht unter dem Copyright der IBM.
Nachricht : PFR9116
*LGLDBIO only valid when *JOBTYPE specified for DATATYPE parameter
Nachrichtenlangtext :
Cause . . . . . : *LGLDBIO was specified for the Y-axis (YAXIS) parameter when a value other than *JOBTYPE was selected for Data type (DATATYPE) parameter.
Recovery . . . : Do one of the following and try the request again:
-- Change the Y-axis (YAXIS) parameter to one of the special values *CPU, *TNS, *NBRTNS, *RSP, *SYNCIO, *NBRSYNC, *ASYNCIO, *NBRASYNC, *TOTDSKIO, *NBRDSKIO, *CMNIOP, *DSKIOP, *LWSIOP, *MFCIOP, *MFDIOP, *DSKARM, *PCTDSKOCC, or *CMNLINE.
-- Change the Data type (DATATYPE) parameter to one of the special values *FCNARA, *PRIORITY, *IOP, *DISK, *CMNLINE, or *ALL.
Nachrichtendatei : QPFRMSGF
Bibliothek Nachrichtendatei : QPFR