Ansicht
Dokumentation

PPE_XPRA_AUTO20_ECC_DIMP500 - Program PPE_XPRA_AUTO20_ECC_DIMP500

PPE_XPRA_AUTO20_ECC_DIMP500 - Program PPE_XPRA_AUTO20_ECC_DIMP500

RFUMSV00 - Advance Return for Tax on Sales/Purchases   Fill RESBD Structure from EBP Component Structure  
This documentation is copyright by SAP AG.
SAP E-Book

Purpose

The XPRA consists of five parts:

1. Conversions in Product Structure Area

The entries PVS variant (COL): Color attributes in table PVCOL are converted in table PCOLMR (master record color key). In the new releases, the color code is checked in the new color key table.

2. Conversions in Process Structure Area

Changes to field HISTFLG in table PALTID, if the relevant PAMODD is maintained with change statuses. In this case, the History indicator must be set to TRUE.

Changes to the time analysis values in table PAMODD. The values 3 and 4 are converted into the values 1 and 2.

Determine activity types. These are blank in the older releases. The system interprets the activity types as production or setup using the values maintained in the fields DURVAR, CRQVAR, DURFIX, and CRQFIX. The values of these fields are the converted into the fields DURATION, DURATION_FIX, CAPREQ, CAPREQFIX. The values in fields RESUID DURATION, DURATION_FIX, CAPREQ, and CAPREQFIX are converted.

3. Conversions in Factory Layout Area

The name of the individual line balance is checked to see if the name contains SPACE. If yes, SPACE must be replaced by an underscore.

4. Conversions in Workbench Area

Mapping of the profile ID from old profiles to new profiles. The old profiles are renamed and their usage is updated in the other tables.

Integration

Prerequisites

Features

Selection

Standard Variants

Output

Activities

The following errors can occur in all areas during conversion. All possible problems, their causes, meaning, and follow-up actions are described in detail.

1. A database error occurred when updating a table

The database changes could not or only partially be made due to database errors. Therefore, you cannot use the data during processing.

Correct the database errors and start the report again manually. No more errors should occur.

2. The proxy object for the APO resource could not be created.

The system could not create the proxy object when converting the APO resource from DI 46C.1. The iPPE resource nodes are also not created. The most important conversion for the factory layout is therefore not carried out.

Check why the proxy object could not be inserted. Correct the database errors and start the report again manually. No more errors should occur. If the error occurs again, create a problem message under the component LO-MD-PPE-FLO.

3. The created iPPE node has no application data.

You have started the XPRA program PPE_XPRA_AUTO20_ECC_DIMP500. In this conversion program, the system converts the APO resources into proxy objects and iPPE resource nodes. This error message appears if there are data inconsistencies that occur when an APO resource is converted. The system could not completely create the resource nodes.

Correct the database errors and start the report again manually. No more errors should occur. If the error occurs again, create a problem message under component LO-MD-PPE-FLO.

The data inconsistencies can be analyzed and corrected with the program PNRES_CONSISTENCY_CHECK. Details about the program are included in the program as comments.

4. No iPPE resource data was found for the created proxy object.

The system has generated the proxy object from the DI 46C.1 APO resource. However, the iPPE resource node could not be created. Your data is now incomplete. This error occurs when there are problems with the database.

Correct the database errors and start the report again manually. No more errors should occur. If problems continue to occur, create a problem message under component LO-MD-PPE-FLO.

5. The GUID of the APO resource in table PAMODD or PAMODC cannot be converted.

You have started the XPRA PPE_XPRA_AUTO20_ECC_DIMP500. When the mode data are upgraded, the values of field RESUID (character 22) are converted into the field PNGUID (character 16). The error message appears when the GUID is not converted successfully.

The conversion is carried out, but information about the usage of the APO resource in the activity mode is lost.

This error is not likely to occur. The usage of the APO resource in the modes must be checked. You can also create a problem message under component LO-MD-PPE_FLO.

12. The EPRA PPE_XPRA_AUTO20_ECC_DIMP500 is not relevant to the current start release.

You have started the XPRA PPE_XPRA_AUTO20_ECC_DIMP500. This program contains the conversions from tables that only exist in the DI release 4.6C1, DI release 4.6C2, DIMP release 4.71 and ECC-DIMP release 500. They are not included in an upgrade process with one of the above-mentioned start releases.

The system does not execute the XPRA program PPE_XPRA_AUTO20_ECC_DIMP500.

Example






CPI1466 during Backup   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by SAP AG.

Length: 5292 Date: 20240531 Time: 233328     sap01-206 ( 93 ms )