Ansicht
Dokumentation

REML_FILL_EABLCONSHIST - Determine Consumption Characteristics for Implausible Meter Readings

REML_FILL_EABLCONSHIST - Determine Consumption Characteristics for Implausible Meter Readings

TXBHW - Original Tax Base Amount in Local Currency   Fill RESBD Structure from EBP Component Structure  
This documentation is copyright by SAP AG.
SAP E-Book

Purpose

This program is used when processing and releasing implausible meter reading results using Machine Learning.

You can use this program to define the characteristics of implausible meter readings, which are used to process and release implausible meter readings using Machine Learning.

Integration

Prerequisites

To use this report, you require authorization for the following objects:

  • E_MR_DOC: You require authorization for the following authorization field:
  • ISU_MR_ACT with the check value '04'

Features

Characteristics of meter readings that correspond to the selection parameters (see group box "Selection Parameters") and other criteria are entered in the table TEML_EABLCONSHST (consumption characteristics for implausible meter reading results).

These criteria are as follows:

  1. Historical meter readings that are over a year old must be available.
  2. A relevant installation must have been determined, which is assigned to the meter reading (see also the BAdI ISU_ML_MR_EABLCONSHIST)

The table TEML_EABLCONSHST contains fields, which were calculated using consumption data, such as the field AVG_NRMLZD_CONS_HIST_VAL. The average value for all normalized historical consumption data is calculated.

Selection

The selection screen contains two group boxes:

  1. The "Selection Parameters" group box contains parameters, which you can use to define the number of meter readings for which characteristics are to be identified (for example only for a specific portion, meter reading unit or division).
  2. The "Meter Reading Data" group box contains two checkbox fields:
  • Historical Results:
    The system only selects meter readings for which a switch to meter reading status ‘2’ has been performed in the past. For more information, see the F1 Help for the checkbox.
    Default setting: Checkbox is not selected.

  • Current Results:
    The system only selects meter readings that are implausible and therefore have meter reading status ‘2’, ‘3’ or ‘5’.
    Default setting: Checkbox is not selected.

Hint: Meter reading documents for which characteristics were already calculated in an earlier program run and saved in the table TEML_EABLCONSHST are not selected again here.

Standard Variants

During regular run of report in batch mode, we recommend using report variants.

Output

The result of the report is provided as WRITE-List.

Precise information about individual records can be investigated using transaction SE16N and the internal document ID.

Activities

Example






ABAP Short Reference   ROGBILLS - Synchronize billing plans  
This documentation is copyright by SAP AG.

Length: 3277 Date: 20240520 Time: 110822     sap01-206 ( 46 ms )