Ansicht
Dokumentation

RNUCNPMC - IS-H: SG NPMI Reconstruct Original Status of Risk Information

RNUCNPMC - IS-H: SG NPMI Reconstruct Original Status of Risk Information

Addresses (Business Address Services)   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by SAP AG.
SAP E-Book

Description

This program lets you handle error messages independently of the normal risk information transaction. It lets you reconstruct the original status of risk factor data whose transmission contained errors, and then transmit it again.

This program has been released for test purposes only.

Enter the patient number or the external ID of the patient for whom you wish to reconstruct the NPMI risk factor data, or search for the patient via error messages from message transmission.
You can usually find patients by means of error message NC423: "Errors detected during data transmission".

Caution: You can change the data once only. This results in the current values (outbound data) being overwritten!

Requirements

To be able to execute this program you require authorization S_PROGRAM with action SUBMIT for report group N_U3_SR.
You also require authorization N_EINR_REP for the desired institution and program RNUCNPMC.
You also have to have authorization to process the patient whose NPMI data you wish to transmit.

Message exchange can only function correctly if Customizing for NPMI is correct.

You can only run this program for IS-H Release 4.03 or later if field NC301S-PATNR is filled (program RNXPRA13 must have been run).

If more than one non-canceled identical risk factors exist, you have to make modifications manually, since the program only takes into account the risk factor with the highest sequence number.

Output

The program resets the status of the risk factors that were transmitted (with errors) in a previous message to "to be sent to NPMI" (NRSF-CSTAT <> SPACE).
If the data is free of errors the system immediately creates a new dispatch order from which the message is created. If the data still contains errors, you have to manually modify it using the transaction for maintaining risk information, before releasing it manually.

The information in program RNC301U2 tells you if the message has actually been transmitted.

Example

A message containing risk factors RF1, RF3 and RF4 was transmitted for patient S123456789 on February 1, 2000. However, the physician specification was missing for RF1. In the meantime, the physician has been entered for RF1, RF3 has been deleted, and RF5 added.
This program would send RF1, RF3, and RF5 as change messages to NPMI, and R4 as a deletion message.
Without program RNUCNPMC, RF3 would not have been sent, since RF3 would have been considered to have already been transmitted.






General Material Data   General Data in Customer Master  
This documentation is copyright by SAP AG.

Length: 2712 Date: 20240520 Time: 095329     sap01-206 ( 46 ms )