Ansicht
Dokumentation

ISU__CE_RPC - Poland: Determine Charge for Reactive Power Consumption

ISU__CE_RPC - Poland: Determine Charge for Reactive Power Consumption

TXBHW - Original Tax Base Amount in Local Currency   ROGBILLS - Synchronize billing plans  
This documentation is copyright by SAP AG.
SAP E-Book

Use

Use this report to calculate amount for excessive reactive power consumption and display this amount in the billing document.

Operands and their Meanings

Input operands

This program uses the following input operands:

  • FACTOR - Stores the coefficient announced by the company (in pricing)
  • QPRICE - Stores the price for electricity [PLN/MWh or PLN/kWh]
  • FACTOR - Stores the company specific coefficient usually defined at contract level. The default value of this coefficient is 0.4
  • QUANT - Stores the amount of active energy consumption
  • QUANT - Stores the amount of reactive power consumption
  • FLAG - Determines the formula to be used for calculation of coefficient for reactive energy actually consumed by customer.

If you set this flag the system calculates the coefficient for reactive energy through this formula:
,,coefficient for reactive energy actually consumed by customer = (amount of reactive energy) / (amount of active ,,energy)
Else it uses this formula:
,,coefficient for reactive energy actually consumed by customer = (amount of reactive energy) / (amount of active ,,energy) + tgphi0

Output operands

This program uses the following output operands:

  • AMOUNT - stores the charge for excessive reactive power consumption

Functionality

This variant program calculates amount for excessive reactive power consumption. For this functionality to work you need to maintain the input operand as follows:

  • Operand one should contain value of coefficient announced by the company (in pricing)
  • Operand three should contain company specific coefficient usually defined at contract level. The default value of this coefficient is 0.4
  • Operand four should contain value of active energy consumption
  • Operand five should contain value of reactive energy consumption
  • Operand six is a flag, based on the value of this flag the formula for calculation of coefficient for reactive energy actually consumed by customer, will vary

Info Lines and Control Options

Info lines are written for the quantity or consumption (in particular, for meter readings in the case of registers).

An info line is written about the calculation method; entries are made in the following fields:

  • ZAHL1 -stores the coefficient announced by the company (in pricing)
  • ZAHL2 - stores the price for electricity [PLN/MWh or PLN/kWh]
  • ZAHL3 - stores the company specific coefficient usually defined at contract level. The default value of this coefficient is 0.4
  • ZAHL4 - stores the amount of active energy consumption
  • ZAHL5 - stores the amount of reactive energy consumption
  • ZAHL6 - stores the amount of excessive reactive power consumption

,,,,,,,,,,,, ,,,,,, ,,,, ,,,,,,

You can suppress the writing of info lines using the control. You can use this control to define which type of operand update occurs:

  • The update adds to existing values
  • The update overwrites existing values

Prerequisites

  • Define the rate step in the Customizing for SAP Utilities, under Contract Billing -> Billing Master Data -> Rate Structure -> Rates -> Define Rates
  • The system displays the amount of excessive reactive power consumption in the billing document under the line item /rpcpl. To enable this, you have to activate the (/SAPCE/BBPINV_PL) BC set





Parameters

XY_OBJ
XY_SOBJ
X_OP
X_RED
X_SS

Exceptions

ACTIVE_ZERO
GENERAL_FAULT
REGULAR_ERROR

Function Group

CE/SAPLIUPL_RPC

General Material Data   General Data in Customer Master  
This documentation is copyright by SAP AG.

Length: 4869 Date: 20240523 Time: 093206     sap01-206 ( 57 ms )