Ansicht
Dokumentation
QRKS_MASTER_CHARACTERISTIC - Control Chart for Master Inspection Characteristic
BAL_S_LOG - Application Log: Log header data Fill RESBD Structure from EBP Component StructureThis documentation is copyright by SAP AG.
Functionality
You can specify the function module QRKS_MASTER_CHARACTERISTIC in an SPC criterion in QM Customizing if you want to use this criterion to maintain quality control charts for a master inspection characteristic (independently of inspection lots and task lists).
The system calls the function module automatically during inspection processing when it calculates the sample size, in order to assign the characteristic to an open control chart. If the search is unsuccessful, the system automatically creates a new control chart.
When the system makes the assignment, it checks the following criteria for compatibility:
- SPC criterion
- Plant for master inspection characteristic
- Number of master inspection characteristic
- Control chart type
If more than one open control chart is available that fulfills all criteria, the system selects the newest control chart.
Example
In a small-scale repetitive manufacturing environment, it may be advisable not to create a new control chart for each production order.
Notes
If you use this function module for an inspection characteristic without a reference to a master inspection characteristic, the system does not assign a control chart.
It is generally not advisable to use this function module for unlocked characteristics with different target values or for material-dependent target values.
Further information
Quality control charts in QM are described in the Implementation Guide and in the online documentation.
Parameters
E_QRKNRI_QALS
I_QAMV
I_QAPO
I_QPSH
I_QPSP
Exceptions
FOREIGN_LOCKINCOMPLETE_SPC_KEY
NO_ENTRY_IN_QPST
Function Group
QRKSCL_GUI_FRONTEND_SERVICES - Frontend Services PERFORM Short Reference
This documentation is copyright by SAP AG.
Length: 2305 Date: 20240523 Time: 134441 sap01-206 ( 33 ms )