Ansicht
Dokumentation

TRINT_TADIR_POPUP - internal: Display/change TADIR entry (maintenance popup, no update)

TRINT_TADIR_POPUP - internal: Display/change TADIR entry (maintenance popup, no update)

Vendor Master (General Section)   TXBHW - Original Tax Base Amount in Local Currency  
This documentation is copyright by SAP AG.
SAP E-Book

You can use this function within the Change and Transport System only, since it updates the database without setting short-term locks (enqueue/dequeue edit locks).

The function displays the object directory entry (TADIR) for the object
given in the WI_TADIR parameter in an online window. The relevant development class (TDEVC) and statements about local existence are transferred by the WI_TDEVC, WI_NO_TADIR and WI_NO_TDEVC parameters.

Which attributes can be changed, depends on the following factors:

  • The parameter WI_READ_ONLY results in display only.
  • All attributes can be changed:
  • for user DDIC

  • if the parameter WI_MASTERFLAG is set

  • Otherwise only the development class, the author and the generation flag (during creation) can be changed in the original system.
  • In the non-original system of the object, a normal user can only change the repair flag.

Furthermore, the parameter WI_EXISTENCE_CHECK can be used so that an existence check takes place.
The parameter WI_MESSAGE_ENTER_DEVCLASS generates the message "Enter a development class" on the POPUP.
The parameter WI_NO_DELETE_FUNCTION suppresses the delete function.

The function returns both the old and new object directory entry (WE_TADIR_OLD, WE_TADIR_NEW) and the new development class (EV_TDEVC).
The parameter WE_DELETE_TADIR indicates whether the entry should be deleted.
The parameter WE_GENERATED_FLAG indicates that the generated flag has been set. The parameter WE_GENERATE_FLAG_REMOVED indicates that the generated flag has been reset.
The parameter WE_REPAIR_FLAG indicates that the repair flag has been set. The parameter WE_REPAIR_FLAG_REMOVED indicates that the repair flag has been reset.
The parameter EV_OBJECT_TRANSPORT indicates whether objects have to be transported, due to changes in the object directory entry. If so, the objects for transport are transferred with table TT_E071. If component objects are already locked, the parameter EV_EDIT_TASK indicates the task with which the user can edit the object.





Parameters

EV_EDIT_TASK
EV_OBJECT_TRANSPORT
EV_TDEVC
IV_NAMESPACE
IV_NAME_TOO_LONG_FOR_OLD
IV_NONSTANDARD_CHARS
IV_REP_CALL
IV_SHOW_ONLY_CHECK_LIKE_INS
IV_SUPPRESS_MOD_SHOW
IV_WBO_INTERNAL
TT_E071
WE_DELETE_TADIR
WE_GENERATED_FLAG_SET
WE_GENERATE_FLAG_REMOVED
WE_REPAIR_FLAG_REMOVED
WE_REPAIR_FLAG_SET
WE_TADIR_NEW
WE_TADIR_OLD
WI_EXISTENCE_CHECK
WI_MASTERFLAG
WI_MESSAGE_ENTER_DEVCLASS
WI_NO_DELETE_FUNCTION
WI_NO_TADIR
WI_NO_TDEVC
WI_READ_ONLY
WI_TADIR
WI_TDEVC

Exceptions

CLOSE
DISPLAY_MODE
EXIT
GLOBAL_TADIR_INSERT_ERROR
NO_MODIFICATION_OF_HEAD_SYST
NO_OBJECT_AUTHORITY
NO_SYSTEMNAME
NO_SYSTEMTYPE
NO_TADIR_TYPE
OBJECT_RESERVED_FOR_DEVCLASS
OBJ_SPECIFICATION_NOT_UNIQUE
PGMID_OBJECT_NOT_ALLOWED
RESERVED_NAME
TADIR_NOT_EXIST

Function Group

STRD

PERFORM Short Reference   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by SAP AG.

Length: 3458 Date: 20240604 Time: 033338     sap01-206 ( 81 ms )