Hi again

Due to a program error or a crash of the application server, IPC
objects (like shared memory segments) remain and prevent a
restart.

The CLEANIPC simply delete all the shared memories of
an R/3 instance once that instance has been shut down.

Kind regards

Susanne Søndermark
KOrsnäs Packaging
Denmark



--- In SAP on System iZy..., "Peri Alberto" <vw000644Zf...> wrote:
> Excuse me Susanne,
>
> But you can explain me what this command do/work????
>
> Thanks
>
> Alberto Peri
> Euroinvest Group
>
>
>
>
> -----Messaggio originale-----
> Da: sondermark [mailto:susoZk...]
> Inviato: venerdì 8 novembre 2002 8.38
> A: SAP on System iZy...
> Oggetto: Re: Cleanipc Program
>
>
> Hi
>
> I executed the CLEANIPC once I couldn't start SAP.
> The command is normally done in the STARTSAP and STOPSAP but in my
> case it didn't.
>
> You should:
>
> - Shut down SAP
> - Log on as QSECOFR
> - Type: CLEANPIC (press F4)
> - Type: <SID>
> - Type: remove (must be lower case)
>
> After running this command I could that WRKSYSSTS reduced the
amount
> of temp-storage and all worked fine again.
>
> Hope it helps you 🙂
>
> Kind regards
>
> Susanne Søndermark
> Korsnäs Packaging
> Denmark
>
>
>
>
>
>
>
>
>
>
>
>
> --- In SAP on System iZy..., "Sugg, Chris" <cgcsuggZn...> wrote:
> > Hi Group.
> >
> > We have some problems with SM20. It worked fine until about the
> 28th of
> > October, then it had problems with no audit files. We have checked
> all
> > parms. for SM19 & SM20 and all are there and meet all the SAP
rules
> (note
> > 539404). The same configuration works fine on our TST box and our
> KW server
> > and the PRD Start Instance also looked ok.
> >
> > From notes 173743 and 12715, it appears we may have a problem with
> our
> > shared memory buffer. We recycled our PRD system this week and
when
> I do
> > SHOWIPC, the numbers for objects and shared memory look vary
> similar to what
> > it was previously.
> >
> > I executed the CLEANIPC program on our DEV system as a test and it
> displayed
> > this message:
> >
> > To inhibit destruction of valid SAP-IPC-Objects
> > during shutdown, this program requires now
> > special options for removing IPC-Objects.
> >
> > Has anyone ever executed this program on the AS400 before? From
> OSS support
> > and OSS notes, it appears to be a valid command for the 400, but
no
> mention
> > of the warning.
> >
> > thanks,
> > Chris S
>
>
> Have a look to our homepage at: http://www.consolut.net