Hi Volker,

I'm not aware of doing anything different.

I setup another printer in SPAD as IBMSCS2 and did a SM50 list print.
This too came out FFT Yes.

We are EBCDIC V5R1, 46D Kernel 1604, 46C Support Package 43.

Our development, QA and Live systems all behave this way.

Regards Steve

--- In DoNotReply@consolut.eu, "Volker Gueldenpfennig"
<volker.gueldenpfennigZs...> wrote:
> Hi Steve,
>
> I tested on my 4.6C EBCDIC system and created a spool from an ABAP
> list (just printed the printers in SPAD).
>
> This worked fine with IBMSCS2 and without FFT turned on.
>
> Are you doing something different ? Using an ASCII system ???
>
> Regards
>
> Volker
>
> --- In DoNotReply@consolut.eu, "s_m_jonesuk"
<Steve_JonesZH...>
> wrote:
> > Thanks Volker,
> >
> > The LPI/CPI is OK on the IBMSCS2, but the problem there is Final
> > Form Text. I have some old spool files around from the 40B
system
> > and in option 8 the only difference on IBMSCS2 with 46C is this
FFT
> > attribute.
> >
> > Can I manipulate that from SAP ?
> >
> > Regards Steve
> >
> >
> >
> > --- In DoNotReply@consolut.eu, "Volker Gueldenpfennig"
> > <volker.gueldenpfennigZs...> wrote:
> > > Hi,
> > >
> > > you are totally right.
> > >
> > > IBMSCS does work with "variable LPI/CPI" which is most likely
> > (100%)
> > > not supported with this old printer.
> > > So, you have to use IBMSCS2 which doesn't do so.
> > >
> > > What CPIs and LPIs are supported on this printer ? Just 10 CPI
or
> > 15
> > > CPI as well ?
> > >
> > > Because I could imagine, that even the QSYSPRT setting on your
> > system
> > > (not the variable one) could cause the printer some headaches.
> > > What CPI and LPI is described with option 8 at the resulting
> > > spoolfile with IBMSCS2 ?
> > >
> > > Regards
> > >
> > > Volker
> > >
> > > --- In DoNotReply@consolut.eu, "s_m_jonesuk"
> > <Steve_JonesZH...>
> > > wrote:
> > > > Hi all,
> > > >
> > > > I'm getting CPA3388 Attributes of file QSYSPRT not supported
> for
> > > > device when printing to a 5256 printer.
> > > >
> > > > I've set it up as both an IBMSCS and an IBMSCS2. Both give
the
> > same
> > > > error. SCS2 seems to pass through Final Form Text, and SCS
> > passes
> > > > variable CPI and LPI attributes.
> > > >
> > > > It is these the printer is complaining about.
> > > >
> > > > How can I change these?
> > > >
> > > > This has only started happening after an upgrade from 4.0B
to
> > 4.6C.
> > > >
> > > > Thanks Steve Jones