Ansicht
Dokumentation
CPA58FE - Controller &24 on line &23 not contacted. Remote disconnect. (C G R) ( OS/400 )
Addresses (Business Address Services) BAL Application Log DocumentationThis documentation is copyright by IBM.
Message : CPA58FE
Controller &24 on line &23 not contacted. Remote disconnect. (C G R)
Message Long Text :
Cause . . . . . : A Disconnect Mode (DM) frame was received from the remote system while attempting to establish an IDLC data link connection.
Recovery . . . : Do one or more of the following:
-- Contact the remote system operator to determine if there is a problem at the remote system.
-- Verify that the controller configuration parameters are correct.
Reply to the message.
If the problem continues, report the problem (ANZPRB command).
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel recovery and inform any applications that are waiting for an operation that the recovery has been canceled.
G -- Start the automatic communications recovery again as defined by the system communications recovery limit (CMNRCYLMT) configured for controller &24.
R -- Try the operation one more time.
Technical description . . . . . . . . : The error code is &40: remote disconnect.
Message File : QCPFMSG
Library Message File : QSYS2924
Addresses (Business Address Services) CL_GUI_FRONTEND_SERVICES - Frontend Services
This documentation is copyright by IBM.
Length: 3269 Date: 20240426 Time: 212215 sap01-206 ( 3 ms )