Ansicht
Dokumentation
CPD26CF - Local address must be 00. ( OS/400 )
RFUMSV00 - Advance Return for Tax on Sales/Purchases ROGBILLS - Synchronize billing plansThis documentation is copyright by IBM.
Message : CPD26CF
Local address must be 00.
Message Long Text :
Cause . . . . . : A value of point-to-point (*PP) was specified for the connection type (CNN parameter), and a value of either *BSCEL, *RPGT, or *BSC38 was specified for the application type (APPTYPE parameter) This requires that the local address (LOCADR parameter) value be specified as hex 00.
Recovery . . . : Do one of the following and then try the request again.
-- Change the local address (LOCADR parameter) value to hex 00.
-- Change the application type to a value other than *BSCEL, *RPGT, or *BSC38.
-- Change the connection type to a value other than *PP.
Message File : QCPFMSG
Library Message File : QSYS2924
CL_GUI_FRONTEND_SERVICES - Frontend Services rdisp/max_wprun_time - Maximum work process run time
This documentation is copyright by IBM.
Length: 3213 Date: 20240426 Time: 162233 sap01-206 ( 2 ms )