CPD271E - Line row &2 security level not correct. ( OS/400 )
SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up CL_GUI_FRONTEND_SERVICES - Frontend ServicesThis documentation is copyright by IBM.
Message : CPD271E
Line row &2 security level not correct.
Message Long Text :
Cause . . . . . : The minimum security level for line row &2 is greater than the maximum security level for the same row. The minimum security level must be less than or equal to the maximum security level within the same row.
Recovery . . . : Specify a minimum security level for line row &2 that is less than or equal to the maximum security level for line row &2, and then try the command again. Security levels are *NONSECURE, *PKTSWTNET, *UNDGRDCBL, *SECURECND, *GUARDCND, *ENCRYPTED, and *MAX in an arrangement of least to most protected.
Message File : QCPFMSG
Library Message File : QSYS2924