Ansicht
Dokumentation
CPD370A - OMITLIB parameter not allowed. ( OS/400 )
General Material Data CPI1466 during BackupThis documentation is copyright by IBM.
Message : CPD370A
OMITLIB parameter not allowed.
Message Long Text :
Cause . . . . . : The OMITLIB parameter is not allowed for one of the following reasons:
-- If this is the Save Library (SAVLIB) command, then the OMITLIB parameter is allowed only when the value for the LIB parameter is specified as *ALLUSR, *IBM or *NONSYS.
-- If this is the Save Changed Object (SAVCHGOBJ) command, then the OMITLIB parameter is allowed only when the value for the LIB parameter is specified as *ALLUSR.
-- If this is the Restore Library (RSTLIB) command, then the OMITLIB parameter is allowed only when the value for the SAVLIB parameter is specified as *ALLUSR, *IBM or *NONSYS.
Recovery . . . : Do one of the following and try the request again:
-- Do not specify the OMITLIB parameter.
-- Specify LIB(*ALLUSR) for the SAVCHGOBJ command.
-- Specify LIB(*ALLUSR, *IBM, or *NONSYS) for the SAVLIB command.
-- Specify SAVLIB(*ALLUSR, *IBM, or *NONSYS) for the RSTLIB command.
Message File : QCPFMSG
Library Message File : QSYS2924
General Material Data Fill RESBD Structure from EBP Component Structure
This documentation is copyright by IBM.
Length: 3226 Date: 20240427 Time: 022707 sap01-206 ( 2 ms )