Message : CPD8E50
Maximum frame size not valid for controller type.

Message Long Text :

Cause . . . . . : The maximum frame size must be specified as follows:
For controller type (TYPE parameter) 3174:
- If the link type (LINKTYPE parameter) is *SDLC the maximum frame size (MAXFRAME parameter) must be 265 or *LINKTYPE.
- If the link type (LINKTYPE parameter) is *IDLC, the maximum frame size (MAXFRAME parameter) must be 265, 521 or *LINKTYPE.
- If the link type (LINKTYPE parameter) is *LAN, the maximum frame size (MAXFRAME parameter) can be any value in the range 265-1994 or *LINKTYPE.
- If the link type (LINKTYPE parameter) is *X25 the maximum frame size (MAXFRAME parameter) must be 256 ,265 or *LINKTYPE.
For controller type (TYPE parameter) 5394:
- If the link type (LINKTYPE parameter) is *SDLC, the maximum frame size (MAXFRAME parameter) must be 261, 517 or *LINKTYPE.
- If the link type (LINKTYPE parameter) is *X25, the maximum frame size (MAXFRAME parameter) must be 256, 265, 512, 521 or *LINKTYPE.
Recovery . . . : Specify a maximum frame size value that is valid for the controller type, then try the request again.