Ansicht
Dokumentation

CPD8F46 - NWI or NWIDLCI parameter value not valid. ( OS/400 )

CPD8F46 - NWI or NWIDLCI parameter value not valid. ( OS/400 )

ROGBILLS - Synchronize billing plans   PERFORM Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD8F46
NWI or NWIDLCI parameter value not valid.

Message Long Text :

Cause . . . . . : The attached nonswitched NWI (NWI parameter) and DLC identifier (NWIDLCI parameter) must either both be *NONE or both be specified as values other than *NONE.
Recovery . . . : Either change the NWI and NWIDLCI parameter values to both be *NONE or specify the name of the attached nonswitched NWI and the DLCI number for this line description.
Technical description . . . . . . . . : The network interface (NWI) parameter specifies the name of the frame relay network interface. And, the network interface data link connection identifier (NWIDLCI) parameter specifies the data link connection identifier to be assigned to this line. If the NWI and NWIDLCI parameters are specified as *NONE, the NWI and NWIDLCI parameters will be configured when the network interface is created. Otherwise, they must both be specified during the configuration of the line.

Message File : QCPFMSG
Library Message File : QSYS2924


SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   RFUMSV00 - Advance Return for Tax on Sales/Purchases  
This documentation is copyright by IBM.

Length: 3225 Date: 20240508 Time: 194338     sap01-206 ( 3 ms )