Ansicht
Dokumentation
CPDB8E2 - A disk device problem was detected. ( OS/400 )
CPI1466 during Backup General Material DataThis documentation is copyright by IBM.
Message : CPDB8E2
A disk device problem was detected.
Message Long Text :
Cause . . . . . : Vary-on of an Auxiliary Storage Pool (ASP) device detected a disk device problem. The source of the error is &2 with 1 being the only or the production copy of the ASP and 2 being the geographic mirroring mirror copy. The reason code is &1.
The reason codes are:
1122 - The Input/Output Processor (IOP) has data in the cache which needs to be discarded.
1124 - Unable to query an IOP for cached data that needs to be discarded.
1214 - Same node owns geographic mirroring production and mirror copies.
Recovery . . . : For codes 1122 and 1124, use the service tools to Reclaim the IOP Cache Storage. For code 1214, switch one of the copies to the other node.
Message File : QCPFMSG
Library Message File : QSYS2924
PERFORM Short Reference BAL_S_LOG - Application Log: Log header data
This documentation is copyright by IBM.